Part Number 80-1479-3 7/10 287
S850/S1000/S1200
Remote - 3 Phase
Caution: Disconnect Power Before Working on Electrical Circuitry
L1
HIGH PRESSURE
CUTOUT
(89)
(88)
CONTROL BOARD
(2)
(6)
(1)
(5)
(7)
(4)
TRANS.
FUSE (7A)
(55)
(61)
CLEAN
ICE THICKNESS PROBE
WATER LEVEL PROBE
LEFT BIN
RIGHT BIN
RMT BIN
WTR PROBE
ICE PROBE
HARV
SL-1
SL-2
(9)
(8)
(56)
BIN SWITCH
(6)
LOW D.C.
VOLTAGE
PLUG
(1)
(2)
COMPRESSOR
(51)
CONTACTOR
CONTACTS
REMOTE
FAN MOTOR
RUN CAPACITOR**
REMOTE CONDENSER
CLEAN
OFF
ICE
CONTACTOR
COIL
SEE SERIAL PLATE FOR VOLTAGE
(20)
(21)
WATER VALVE
AIR PUMP
WHEN USED
(22)
(28)
(99)
HARVEST
SOLENOID
(27)
DUMP
SOLENOID
(60)
(77)
WATER
PUMP
(76)
(80)
(81)
L2
(57)
(58)
(59)
(98)
(75)
(74)
(42)
L1
* - COMPRESSOR HAS INTERNAL OVERLOAD
* * - SOME AIR COOLED MODELS MAY NOT HAVE RUN CAPACITOR ON FAN MOTOR
L3
L2
L3
T2
T3
T1
(79)
(78)
HPR
SOLENOID
LIQUID
SOLENOID
(83)
(82)
(F2)
(F1)

Table of Contents

Other manuals for Manitowoc SY0324A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc SY0324A and is the answer not in the manual?

Manitowoc SY0324A Specifications

General IconGeneral
BrandManitowoc
ModelSY0324A
CategoryIce Maker
LanguageEnglish

Related product manuals