EasyManuals Logo
Home>Manitowoc>Ice Maker>SY0424A

Manitowoc SY0424A User Manual

Manitowoc SY0424A
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #285 background imageLoading...
Page #285 background image
Part Number 80-1479-3 7/10 285
S500
Remote - 1 Phase
Caution: Disconnect Power Before Working on Electrical Circuitry
L1
HIGH PRESSURE
CUTOUT
(89)
(88)
CONTROL BOARD
(2)
(6)
(1)
(5)
(7)
(4)
TRANS.
FUSE (7A)
(61)
CLEAN
ICE THICKNESS PROBE
WATER LEVEL PROBE
LEFT BIN
RIGHT BIN
RMT BIN
WTR PROBE
ICE PROBE
HARV
SL-1
SL-2
(9)
(8)
(56)
BIN SWITCH
(6)
LOW D.C.
VOLTAGE
PLUG
(1)
(2)
R
S
C
COMPRESSOR
TERMINAL LAYOUT
VIEWED FROM END
OF COMPRESSOR
COMPRESSOR
R
S
C
OVERLOAD INTERNAL
(230V 50/60 HZ)
(48)
(47)
(46)
CONTACTOR
CONTACTS
POTENTIAL
RELAY
(86)
REMOTE CONDENSER
RUN
CAPACITOR
(53)
(44)
START
CAPACITOR
(52)
(49)
(45)
REMOTE
FAN MOTOR
RUN CAPACITOR
(51)
(50)
4
1
5
2
(F1)
(F2)
CLEAN
OFF
ICE
CONTACTOR
COIL
SEE SERIAL PLATE FOR VOLTAGE
(20)
(21)
WATER VALVE
AIR PUMP
WHEN USED
(22)
(28)
(99)
HARVEST
SOLENOID
(27)
DUMP
SOLENOID
(60)
(77)
WATER
PUMP
(76)
(80)
(81)
L2 OR N
(57)
(58)
(59)
(98)
(75)
(74)
(42)
L1
* - COMPRESSOR HAS INTERNAL OVERLOAD
* * - SOME AIR COOLED MODELS MAY NOT HAVE
RUN CAPACITOR ON FAN MOTOR
(78)
(79)
(82)
LIQUID LINE
SOLENOID
(83)
HPR
SOLENOID

Table of Contents

Other manuals for Manitowoc SY0424A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc SY0424A and is the answer not in the manual?

Manitowoc SY0424A Specifications

General IconGeneral
BrandManitowoc
ModelSY0424A
CategoryIce Maker
LanguageEnglish

Related product manuals