3) Indoor Unit Preparation
The refrigerant piping can be routed to the unit in 5
direction, by using the cut outs in the unit casing.
(See fig. 1)
Carefully bend the pipes to the required position to
align with the hole. For right hand and rear side draw
out, hold the bottom of the piping and fix direction
before shaping it to the desired position (See fig. 2).
The condensation drain hose should be taped to the
pipes with vinyl tape. The electrical cable can also be
taped to the pipes.
4) Mounting Indoor Unit
Hook the indoor unit onto the upper portion of installation plate. (Engage the 2 hooks of rear top of the indoor unit with
the upper edge of the installation plate). Ensure the hooks are properly seated on the installation plate by moving in left
and right.
5) Water Drainage Piping
The indoor drain pipe must be downward gradient for smooth drainage. Avoid situation as shown in figure
below.
fig. 2
WOODEN
FRAME WALL
REINFORCED CONCRETE BUILDING
NUT ANCHOR BOLT ANCHOR
Fixing method:-