• Make sure that valve cap and emergency drain hose are reinstalled properly, cap
plates should be inserted aligning to hole plates otherwise water may leak;
• When the appliance is in use and depending on the program selected there can
be hot water in the pump. Never remove the pump cover during a wash cycle, always
wait until the appliance has finished the cycle, and is empty. When replacing the
cover, ensure it is securely re-tightened.
Cleaning drain pump filter
Be careful of the hot water!
Allow detergent solution to cool down.
• Unplug the machine to avoid electrical shock before washing.
• Drain pump filter can filter the yarns and small foreign matters from the
washing.
• Clean the filter periodically to ensure the normal operation of washing
machine.
1
2
3
5
4
Warning!
10
19
Caution!
Open the filter by turning
to the counter clockwise
Remove extraneous matter
Drain the water out of the
pump, under which use a
container to collect.
Restore it and adjust the convex
place to align at the pump hole.
Clean the filter.
Tighten the pump
cover clockwise.
6
Only for washers having these function.