47
9.3.11 Inverter compressor drive error diagnosis and solution(P4)
Error Code
P4
Malfunction decision
conditions
An abnormal inverter compressor drive is detected by a special
detection circuit, including communication signal detection,
voltage detection, compressor rotation speed signal detection
and so on.
Supposed causes Wiring mistake
IPM malfunction
Outdoor fan assy faulty
Compressor malfunction
Outdoor PCB faulty
Trouble shooting: