1. BEFORE INSTALLATION
1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.
 %HVXUHWRREVHUYHWKHZDUQLQJVDQGFDXWLRQVVSHFL¿HGKHUHDVWKH\LQFOXGHLPSRUWDQWLWHPVUHODWHGWRVDIHW\
After reading this manual, be sure to keep it together with the OPERATING INSTRUCTIONS for future reference.
1-2. SELECTING THE INSTALLATION LOCATION
1-3. SPECIFICATIONS
CAUTION
(Could lead to serious injury in particular environments when operated incorrectly.)
INDOOR UNIT
 :KHUHDLUÀRZLVQRWEORFNHG
Where cool air spreads over the entire room.
Rigid wall without vibration.
 :KHUHLWLVQRWH[SRVHGWRGLUHFWVXQVKLQH'RQRWH[SRVHWR
direct sunshine also during the period following unpacking to
before use.
Where easily drained.
 $W DGLVWDQFH P RUPRUHDZD\IURP\RXU79 DQG UDGLR
Operation of the air conditioner may interfere with radio or
79 UHFHSWLRQ $Q DPSOL¿HU PD\ EH UHTXLUHG IRU WKH DIIHFWHG
device.
 ,Q D SODFH DV IDU DZD\ DV SRVVLEOH IURP ÀXRUHVFHQW DQG LQ-
candescent lights (so the infrared remote control can operate
the air conditioner normally).
 :KHUHWKHDLU¿OWHUFDQEHUHPRYHGDQGUHSODFHGHDVLO\
REMOTE CONTROLLER
Where it is easy to operate and easily visible.
Where children cannot touch it.
 6HOHFWDSRVLWLRQDERXWPDERYHWKHÀRRUDQGFKHFNWKDW
signals from the remote controller are surely received by the
indoor unit from that position (‘beep’ or ‘beep beep’ receiving
tone sounds). After that, attach remote controller holder to a
pillar or wall and install wireless remote controller.
Note:
,Q URRPV ZKHUH LQYHUWHU W\SH ÀXRUHVFHQW ODPSV DUH XVHG WKH
signal from the wireless remote controller may not be received.
OUTDOOR UNIT
 :KHUHLWLVQRWH[SRVHGWRVWURQJZLQG
 :KHUHDLUÀRZLVJRRGDQGGXVWOHVV
Where rain or direct sunlight can be avoided as much as pos
-
sible.
Where neighbours are not annoyed by operation sound or
hot air.
Where rigid wall or support is available to prevent the in-
crease of operation sound or vibration.
Where there is no risk of combustible gas leakage.
When installing the unit at a high level, be sure to secure the
unit legs.
Where it is at least 3 m away from the antenna of TV set or
radio. Operation of the air conditioner may interfere with radio
or TV reception in areas where reception is weak. An ampli-
¿HUPD\EHUHTXLUHGIRUWKHDIIHFWHGGHYLFH
Install the unit horizontally.
Please install it in an area not affected by snowfall or blowing
snow. In areas with heavy snow, please install a canopy, a
SHGHVWDODQGRUVRPHEDIÀHERDUGV
Note:
It is advisable to make a piping loop near outdoor unit so as to
reduce vibration transmitted from there.
&RQQHFW WR WKH SRZHU VZLWFK ZKLFK KDV D JDS RI  PP RU
more when open to interrupt the source power phase. (When
the power switch is shut off, it must interrupt all phases.)
8VHZLUHVLQFRQIRUPLW\ZLWKGHVLJQ,(&
1HYHUXVHSLSHVZLWKWKLFNQHVVOHVVWKDQVSHFL¿HG7KHSUHV
-
VXUHUHVLVWDQFHZLOOEHLQVXI¿FLHQW
8VHDFRSSHUSLSHRUDFRSSHUDOOR\VHDPOHVVSLSH
%HFDUHIXOQRWWRFUXVKRUEHQGWKHSLSHGXULQJSLSHEHQGLQJ
5HIULJHUDQWSLSHEHQGLQJUDGLXVPXVWEHPPRUPRUH
,I SLSH OHQJWK H[FHHGV PDGGLWLRQDO UHIULJHUDQW 5$
charge is required. (No additional charge is required for pipe
OHQJWKOHVVWKDQP
$GGLWLRQDOUHIULJHUDQW $îSLSHOHQJWKP±
,QVXODWLRQPDWHULDO+HDWUHVLVWLQJIRDPSODVWLFVSHFL¿F
gravity
%H VXUH WR XVH WKH LQVXODWLRQ RI VSHFL¿HG WKLFNQHVV ([FHV-
sive thickness may cause incorrect installation of the indoor
XQLWDQGLQVXI¿FLHQWWKLFNQHVVPD\FDXVHGHZGULSSDJH
Note:
When operating the air conditioner in low outside temperature,
be sure to follow the instructions described below.
Never install the outdoor unit in a place where its air inlet/
RXWOHWVLGHPD\EHH[SRVHGGLUHFWO\WRZLQG
 7R SUHYHQW H[SRVXUH WR ZLQG LQVWDOO WKH RXWGRRU XQLW ZLWK
its air inlet side facing the wall.
 7RSUHYHQWH[SRVXUHWRZLQGLWLVUHFRPPHQGHGWRLQVWDOOD
EDIÀHERDUGRQWKHDLURXWOHWVLGHRIWKHRXWGRRUXQLW
Avoid the following places for installation where air conditioner
trouble is liable to occur.
 :KHUHÀDPPDEOHJDVFRXOGOHDN
Where there is much machine oil.
 :KHUH RLO LV VSODVKHG RU ZKHUH WKH DUHD LV ¿OOHG ZLWK RLO\
smoke (such as cooking areas and factories, in which the
properties of plastic could be changed and damaged).
Salty places such as the seaside.
 :KHUHVXO¿GHJDVLVJHQHUDWHGVXFKDVDKRWVSULQJ
Where there is high-frequency or wireless equipment.
Where there is emission of high levels of VOCs, includ
-
ing phthalate compounds, formaldehyde, etc., which may
cause chemical cracking.
WARNING
(Could lead to death, serious injury, etc.)
Model 3RZHUVXSSO\ :LUHVSHFL¿FDWLRQV
Pipe size
WKLFNQHVV
Indoor unit Outdoor unit
Rated
Voltage
Frequency
Breaker
capacity
Power supply
Indoor/outdoor
connecting wire
Gas / Liquid
06=()9(:%6
06=()9(:%6
9 +]
——
FRUH
PP
¡PP
PP
06=()9(:%6
06=()9(:%6
06=()9(:%6
08=()9(+
08=()9(+
08=()9(
$
3-core
PP
06=()9(:%6 08=()9( $
3-core
PP
¡PP
PP
()()
Pipe length and height difference
0D[SLSHOHQJWK P
0D[KHLJKWGLIIHUHQFH P
0D[QXPEHURIEHQGV 
5HIULJHUDQWDGMXVWPHQW$ JP
Insulation thickness *8, *9 8 mm
N
Do not install the unit by yourself (user).
,QFRPSOHWH LQVWDOODWLRQ FRXOG FDXVH ¿UH HOHFWULF VKRFN LQMXU\
due to the unit falling, or leakage of water. Consult the dealer
IURPZKRP\RXSXUFKDVHGWKHXQLWRUDTXDOL¿HGLQVWDOOHU
N
Perform the installation securely referring to the instal-
lation manual.
,QFRPSOHWHLQVWDOODWLRQFRXOGFDXVH¿UHHOHFWULFVKRFNLQMXU\
due to the unit falling, or leakage of water.
N
When installing the unit, use appropriate protective
equipment and tools for safety.
Failure to do so could cause injury.
N
Install the unit securely in a place which can bear the
weight of the unit.
If the installation location cannot bear the weight of the unit,
the unit could fall causing injury.
N
(OHFWULFDOZRUNVKRXOGEHSHUIRUPHGE\DTXDOL¿HGH[SH-
rienced electrician, according to the installation manual.
%HVXUHWRXVHDQH[FOXVLYHFLUFXLW'RQRWFRQQHFWRWKHU
electrical appliances to the circuit.
,IWKHFDSDFLW\RIWKHSRZHUFLUFXLWLVLQVXI¿FLHQWRUWKHUHLVLQFRP-
SOHWHHOHFWULFDOZRUNLWFRXOGUHVXOWLQD¿UHRUDQHOHFWULFVKRFN
N
Earth the unit correctly.
Do not connect the earth to a gas pipe, water pipe, lightning rod
or telephone earth. Defective earthing could cause electric shock.
N
'R QRW GDPDJH WKH ZLUHV E\ DSSO\LQJ H[FHVVLYH SUHV-
sure with parts or screws.
'DPDJHGZLUHVFRXOGFDXVH¿UHRUHOHFWULFVKRFN
N
Be sure to cut off the main power in case of setting up
the indoor P.C. board or wiring works.
Failure to do so could cause electric shock.
N
8VH WKH VSHFL¿HG ZLUHV WR FRQQHFW WKH LQGRRU DQG RXW-
door units securely and attach the wires firmly to the
terminal block connecting sections so the stress of the
ZLUHV LV QRW DSSOLHG WR WKH VHFWLRQV 'R QRW H[WHQG WKH
wires, or use intermediate connection.
,QFRPSOHWHFRQQHFWLQJDQGVHFXULQJFRXOGFDXVH¿UH
N
'RQRWLQVWDOOWKHXQLWLQDSODFHZKHUHLQÀDPPDEOHJDV
may leak.
If gas leaks and accumulates in the area around the unit, it
FRXOGFDXVHDQH[SORVLRQ
N
Do not use intermediate connection of
the power cord
RUWKHH[WHQVLRQFRUGDQGGRQRWFRQQHFWPDQ\GHYLFHV
to one AC outlet.
,W FRXOG FDXVH D ¿UH RU DQ HOHFWULF VKRFN GXH WR GHIHFWLYH
FRQWDFWGHIHFWLYHLQVXODWLRQH[FHHGLQJWKHSHUPLVVLEOHFXU-
rent, etc.
N
%HVXUHWRXVHWKHSDUWVSURYLGHGRUVSHFL¿HGSDUWVIRU
the installation work.
The use of defective parts could cause an injury or leakage
RIZDWHUGXHWRD¿UHDQHOHFWULFVKRFNWKHXQLWIDOOLQJHWF
N
When plugging the power supply plug into the outlet,
make sure that there is no dust, clogging, or loose
parts in both the outlet and the plug. Make sure that the
power supply plug is pushed completely into the outlet.
If there is dust, clogging, or loose parts on the power sup
-
SO\SOXJRUWKHRXWOHWLWFRXOGFDXVHHOHFWULFVKRFNRU¿UH,I
loose parts are found on the power supply plug, replace it.
N
Attach the electrical cover to the indoor unit and the
service panel to the outdoor unit securely.
If the electrical cover of the indoor unit and/or the service
panel of the outdoor unit are not attached securely, it could
UHVXOWLQD¿UHRUDQHOHFWULFVKRFNGXHWRGXVWZDWHUHWF
N
When installing, relocating, or servicing the unit, make
VXUHWKDWQRVXEVWDQFHRWKHUWKDQWKHVSHFL¿HGUHIULJHU-
ant (R410A) enters the refrigerant circuit.
Any presence of foreign substance such as air can cause
DEQRUPDOSUHVVXUHULVHDQGPD\UHVXOWLQH[SORVLRQRULQMXU\
7KHXVH RI DQ\ UHIULJHUDQW RWKHU WKDQ WKDW VSHFL¿HG IRU WKH
system will cause mechanical failure, system malfunction, or
unit breakdown. In the worst case, this could lead to a seri-
ous impediment to securing product safety.
N
Do not discharge the refrigerant into the atmosphere. If
refrigerant leaks during installation, ventilate the room.
,IUHIULJHUDQWFRPHVLQFRQWDFWZLWKD¿UHKDUPIXOJDVFRXOG
be generated. Refrigerant leakage may cause suffocation.
3URYLGHYHQWLODWLRQLQDFFRUGDQFH
ZLWK(1
N
Check that the refrigerant gas does not leak after instal-
lation has been completed.
If refrigerant gas leaks indoors, and comes into contact with
WKHÀDPHRIDIDQKHDWHUVSDFHKHDWHUVWRYHHWFKDUPIXO
substances will be generated.
N
Use appropriate tools and piping materials for installa-
tion.
7KHSUHVVXUHRI5$LVWLPHVPRUHWKDQ51RWXV-
ing appropriate tools or materials and incomplete installation
could cause the pipes to burst or injury.
N
When pumping down the refrigerant, stop the compres-
sor before disconnecting the refrigerant pipes.
If the refrigerant pipes are disconnected while the compres-
sor is running and the stop valve is open, air could be drawn
in and the pressure in the refrigeration cycle could become
abnormally high. This could cause the pipes to burst or in-
jury.
N
When installing the unit, securely connect the refriger-
ant pipes before starting the compressor.
If the compressor is started before the refrigerant pipes are
connected and when the stop valve is open, air could be
drawn in and the pressure in the refrigeration cycle could
become abnormally high. This could cause the pipes to
burst or injury.
N
)DVWHQDÀDUHQXWZLWKD WRUTXH ZUHQFK DV VSHFL¿HGLQ
this manual.
,IIDVWHQHGWRR WLJKW DÀDUH QXW PD\EUHDNDIWHU D ORQJSH-
riod and cause refrigerant leakage.
N
The unit shall be installed in accordance with national
wiring regulations.
N
Install an earth leakage breaker depending on the instal-
lation place.
If an earth leakage breaker is not installed, it could cause
electric shock.
N
Perform the drainage/piping work securely according to
the installation manual.
If there is defect in the drainage/piping work, water could
drop from the unit, soaking and damaging household goods.
N
'RQRW WRXFK WKH DLU LQOHW RU WKH DOXPLQXP ¿QV RI WKH
outdoor unit.
This could cause injury.
N
Do not install the outdoor unit where small animals may
live.
If small animals enter and touch the electric parts inside the
XQLWLW FRXOG FDXVH D PDOIXQFWLRQ VPRNH HPLVVLRQ RU ¿UH
Also, advise user to keep the area around the unit clean.
Required Tools for Installation
Phillips screwdriver
Level
Scale
Utility knife or scissors
PPKROHVDZ
Torque wrench
Wrench (or spanner)
PPKH[DJRQDOZUHQFK
)ODUHWRROIRU5$
*DXJHPDQLIROGIRU5$
9DFXXPSXPSIRU5$
&KDUJHKRVHIRU5$
Pipe cutter with reamer
-*5+
SPLIT-TYPE AIR CONDITIONERS
INSTALLATION MANUAL
ENGLISH
English is
original.
Model names are indicated in 1-3.
When installing multi units, refer to the
installation manual of the multi unit for
outdoor unit installation.

Other manuals for Mitsubishi Electric MSZ-EF18VE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric MSZ-EF18VE and is the answer not in the manual?

Mitsubishi Electric MSZ-EF18VE Specifications

General IconGeneral
BrandMitsubishi Electric
ModelMSZ-EF18VE
CategoryAir Conditioner
LanguageEnglish

Related product manuals