Job Name: Location: Date:
Purchaser: Engineer:
Submitted to: For Reference Approval Construction
System Designation: Schedule No.:
Zoning
Cooling Capacity*............................14,000 Btu/h
Heating Capacity*............................18,000 Btu/h
* Rating Conditions (Cooling) - Indoor: 80ºF (27ºC) DB, 67ºF (19ºC) WB; Outdoor: 95ºF
(35ºC) DB, 75ºF (24ºC) WB.
(Heating at 47ºF) - Indoor: 70ºF (21ºC) DB, 60ºF (16ºC) WB; Outdoor: 47ºF (8ºC) DB, 43ºF (6ºC) WB.
(For data on specic indoor units [all ducted, all non-ducted, and both ducted
and non-ducted] combinations, see the MXZ-B Technical and Service Manual.)
Electrical Requirements
Power Supply ....................208 / 230V, 1-Phase, 60 Hz
MCA .............................................. 1 A
Voltage
Indoor - Outdoor S1-S2 ......................AC 208 / 230V
Indoor - Outdoor S2-S3 .........................DC 12-24V
Indoor - Remote Controller.........................Wireless
(Optional Wired Controller: DC 12V)
Fan Motor ....................................0.76 F.L.A.
Airow (Quiet - Lo - Med - Hi - Super Hi)
Cooling .....................205 - 272 - 335 - 420 - 533 Dry CFM
170 - 237 - 300 - 385 - 498 Wet CFM
Heating ...................205 - 247 - 304 - 367 - 463 CFM
Sound Pressure Level (Quiet - Lo - Med - Hi - Super Hi)
Cooling ......................... 26 - 32 - 38 - 44 - 49 dB(A)
Heating ......................... 26 - 30 - 35 - 40 - 46 dB(A)
DIMENSIONS UNIT INCHES / MM
W 31-7/16 / 799
D 9-1/8 / 232
H 11-5/8 / 295
Weight. ......................................22 lbs. / 10 kg
External Finish ......................Munsell No. 1.0Y 9.2 / 0.2
Field Drainpipe Size O.D....................... 5/8" / 15.88 mm
Remote Controller .................................Wireless
(Optional Wired Remote Controller PAR-21MAA;
see Data Submittal Sheet)
Refrigerant Type .....................................R410A
Refrigerant Pipe Size O.D.
Gas Side .................................. 1/2" / 12.7 mm
Liquid Side................................. 1/4" / 6.35 mm
Connection Method ..................................Flared
SUBMITTAL DATA: MSZ-GE15NA. . . . . .15,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-B MULTI-ZONE HEAT-PUMP SYSTEMS
OPTIONAL ACCESSORIES
• M-NET Control Adapter (MAC-399IF)
• MA Contact Terminal Interface (MAC-397IF)
• Wired Remote Controller (PAR-21MAA; requires MAC-397IF)
• Condensate Pump (230V; SI3100-230)
• Anti-allergy Enzyme Filter (Two pieces per set; MAC-408FT-E)
GENERAL FEATURES
• Wall-mounted indoor unit
• Standard Hybrid Catechin Prelter is included with indoor unit
• Quiet operation
• Choice of fan speeds: Quiet, Low, Medium, High, and Super High;
Auto fan speed control also included
• Wireless remote controller is included; PAR-21MAA wired
remote controller can be installed as an option
• Indoor unit powered from outdoor unit using A-Control
• Auto restart following a power outage
• Limited warranty: ve years on parts and defects and seven years
on compressors
Indoor Unit: MSZ-GE15NA
Wireless Remote Controller
MXZ-B SERIES HEAT-PUMP OUTDOOR UNITS
SEZ-KD and PEAD-A24
Remote Controller PAR-21MAA - Packaged
with PCA-KA, PLA-ABA, SEZ, and PEAD
MSZ-GE06,09,12,15,18NA and MSZ-GA24NA
MXZ-B MULTI-ZONE SYSTEMS CAN INCLUDE:
• Ducted Indoor Units:
SEZ-KD09,12,15,18NA, PEAD-A24AA
• Nonducted Indoor Units:
MSZ-GE06,09,12,15,18NA, MSZ-GA24NA,
MSZ-FE09,12NA, MFZ-KA09,12,18NA,
PCA-A24KA, and PLA-A12,18,24BA
• A combination of both Ducted and Nonducted
Indoor Units
Refer to the separate submittal forms for the
MSZ-GE, MSZ-GA, MSZ-FE, SEZ-KD, PEAD,
PCA, PLA Indoor Units, and MXZ Outdoor Units.
Wireless Remote Controller -
Packaged with MSZ-GE, -GA,
-FE and MFZ-KA (Optional Wired
Remote Controller PAR-21MAA)
Outdoor Unit: MXZ-3B30NA
MSZ-FE
MFZ-KA
PCA-KA
PLA-A12,18,24BA