How to disable “AUTO RESTART FUNCTION”
1Turn OFF the main power for the unit.
2Pull out the electronic control P.C. board, the receiver P.C.
board and the display P.C. board. (Refer to 10-1.2.)
3Solder jumper wire to JR07 on the indoor
electronic control P.C. board. (Refer to 9-6.)
Operation
1If the main power has been cut, the operation settings remain.
2After the power is restored, the unit restarts automatically according to the memory.(However, it takes at least 3 minutes
for the compressor to start running.)
NOTE
The operation settings are memorized when 10 seconds have passed after the remote controller was operated with the
remote controller.
If main power is turned OFF or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled.
If the unit has been OFF with the remote controller before power failure, the auto restart function does not work as the
power button of the remote controller is OFF.
To prevent breaker OFF due to the rush of starting current, systematize other home appliances not to turn ON at the same
time.
When some air conditioners are connected to the same supply system, if they are operated before power failure, the
starting current of all the compressors may flow simultaneously at restart.
Therefore, the special counter-measures are required to prevent the main voltage-drop or the rush of the starting current
by adding to the system that allows the units to start one by one.
When the indoor unit is controlled with the remote controller, the operation mode, set temperature, and the fan speed are
memorized by the indoor electronic control P.C. board. “AUTO RESTART FUNCTION” automatically starts operation in the
same mode just before the shutoff of the main power. However if the unit is operated in “I FEEL CONTROL” mode before
power failure, the operation is not memorized. In “I FEEL CONTROL” mode, the operation is decided by the initial room
temperature.
8-3. AUTO RESTART FUNCTION
OB367D-1.qxp 12.1.13 7:49 AM Page 11
OB367D
Downloaded from AC-Manual.com Manuals

Other manuals for Mitsubishi MSH-GA50VB