OPERATING PROCEDURE PHOTOS
5. Removing the compressor (A, B)
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the relay panel.
(3) Remove the soundproof felt.
(4) Remove the terminal cover on the compressor.
(5) Disconnect lead wires from the compressor.
(6) Recover gas from the refrigerant circuit.
NOTE:Recover gas from the pipes until the pressure
gauge shows 0 kg/cm
2
(0 MPa).
(7) Disconnect the welded part of the discharge pipe.
(8) Disconnect the welded part of the suction pipe.
(9) Remove nuts fixing the compressor.
(
10
)
Remove the compressor.
6. Removing the compressor (C)
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the relay panel. (Refer to 2.)
(3) Remove the screws fixing back panel.
(4) Remove the back panel.
(5) Remove the soundproof felt.
(6) Remove the terminal cover on the compressor.
(7) Disconnect lead wires from the compressor.
(8) Recover gas from the refrigerant circuit.
NOTE:Recover gas from the pipes until the pressure
gauge shows 0 kg/cm
2
(0 MPa).
(9) Disconnect the welded part of the discharge pipe.
(
10
)
Disconnect the welded part of the suction pipe.
(
11
)
Remove nuts fixing the compressor.
(
12
)
Remove the compressor.
Photo 5
Terminal cover
Suction pipe
Discharge pipe
Soundproof felt
Terminal cover