'11 • SCM-SM-110
Error code
Remote controller:
LED Green Red
Indoor
Keeps flashing
Stays OFF
Content
E47
Active lter voltage error
Model SCM40, 45, 50, 60, 71, 80
Outdoor
2
times ash
1. Applicable model
5. Troubleshooting
Model SCM40, 45, 50, 60, 71, 80
only
Diagnosis Countermeasure
YES
YES
NO
Is the power supply normal?
NO
Check
soldered surfaces on the
outdoor sub PCB for foreign matter
like dust, fouling,
etc.
YES
Is voltage
within the specified range?
NO
Restore normal condition.
Restore normal condition.
Remove foreign matter like
dust, fouling, etc.
Defective outdoor sub PCB
Replace.
2. Error detection method
Error is displayed if the
converter voltage exceeds
DC340V (3 times within 20
minutes). Remote controller
may be set after 3 minutes
delay.
3.
Condition of Error displayed
Same as above
4. Presumable cause
Defective outdoor sub PCB
Dust on outdoor sub PCB
Anomalous power supply
Note:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SCM125ZJ-S1 and is the answer not in the manual?

Mitsubishi SCM125ZJ-S1 Specifications

General IconGeneral
BrandMitsubishi
ModelSCM125ZJ-S1
CategoryAir Conditioner
LanguageEnglish

Related product manuals