1-5
Model SRK288HENF-L (Indoor unit)
SRC288HENF-L (Outdoor unit)
Item
Model
SRK288HENF-L SRC288HENF-L
Cooling capacity
(1)
W 2500/2500
Heating capacity
(1)
W 2900/3000
Power source 1 Phase, 220/240V, 50Hz
Cooling input kW 0.930/1.005
Running current (Cooling) A 4.5/4.6
Heating input kW 0.83/0.91
Running current (Heating) A 4.0/4.1
Inrush current A 18.2/19.6
COP (In cooling) 2.69/2.49
Noise level
(5)
dB(A) Cooling:38/39 Heating:38/41 Cooling:41/42 Heating:42/43
Exterior dimensions
Height x Width x Depth
mm 275 x 790 x 174 542 x 795 x 255
Color Off white Polar white
Net weight kg 7.5 33
Refrigerant equipment
Compressor type & Q’ty
– RM5512GNE1 (Rotary type) x 1
Motor kW – 0.9
Starting method – Line starting
Heat exchanger Louver fins & inner grooved tubing
Refrigerant control Capillary tubes
Refrigerant
(4)
kg R22 0.88
Refrigerant oil R 0.35 (SUNISO Z300HDS)
Defrost control MC control
Air handling equipment
Fan type & Q’ty
Tangential fan x 1 Propeller fan x 1
Motor W 16 11
Air flow (at High) (Cooling) 7.5/7.5 23
(Heating)
CMM
8.0/8.0 23
Air filter, Q’ty Polypropylene net (washable) x 2 –
Shock & vibration absorber – Cushion rubber (for compressor)
Electric heater ––
Operation control
Operation switch
Wireless–Remote controller –
Room temperature control MC. Thermostat –
Pilot lamp RUN (Green), TIMER (Yellow) –
Safety equipment
–
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
O.D mm(in) Liquid line: ø6.35 (1/4") Gas line: ø9.52 (3/8")
Connecting method Flare connecting
Attached length of piping Liquid line: 0.4m
Gas line: 0.35m
–
Insulation Necessary (Both sides)
Drain hose Connectable
Power source cord 2.5m (3 cores with Earth)
Connection Size x Core number 1.5mm
2
x 5 cores (Including earth cable)
wiring
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit
Optional parts –
Notes (1) The data are measured at the following conditions.
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27ºC 19ºC 35ºC 24ºC JIS C9612, ISO-T1
Heating 20ºC – 7ºC 6ºC JIS C9612, ISO-T1
(2) The operation data are applied to the 220V or 240V districts respectively
(3) Limitation of Voltage application Minimum: 198V Maximum: 264V
(4) The refrigerant quantity to be charged includes the refrigerant in 7.5m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, (when it is less 10 m, add 20g refrigerant per meter and when it is 10 to 15m, add 30g refrigerant
per meter.)
(5) Expressed in sound pressure level.