1-58
(c) When switching to automatic operation during “Heating” “Cooling” “Dry” or when restarting with in 30 minutes (40 : 1
hour) after stopping with automatic operation mode, the former operating mode is selected. (In this case, 20 seconds Lo
operation of indoor fan is not performed). When the previous mode is in “FAN”, operation mode is to be set by the above
mentioned chart.
Wireless remote control signal (Indication)
-6 -5 -4 -3 -2 -1 ±0+1+2+3+4+5+6
Cooling 20 21 22 23 24 25 26 27 28 29 30 31 32
Thermal dry 19 20 21 22 23 24 25 26 27 28 29 30 31
Heating 19 20 21 22 23 24 25 26 27 28 29 30 31
Temperature
setting
(5) Comfort timer settings
Temperature is checked beginning 1 hour before the set time, and the power is turned on before the timer setting as necessary to
bring the temperature to the proper level by the set time.
Operation mode Room temperature thermistor (Th1)
Operating start time (amount of time
previous to set time that operation begins)
Under 5˚C 60 mins.
Heating Under 10˚C 30 mins.
Under 15˚C 15 mins.
Over 40˚C 60 mins.
Cooling Over 35˚C 30 mins.
Over 30˚C 15 mins.
Notes (1) At 5 minutes before the set time of
the turn-on timer, the operation is
started regardless of the tempera-
ture of the room temperature
thermister.
(2) When the dry or blow operation is
selected, this function is not acti-
vated.
(However, when the automatic dry
operation is selected, the function
described in article (1) is operated.)
(d) Established temperature (operate by the established temperature button on remote controller).