1-18
(2) The operation data are applied to the 220 V or 240 V districts respectively.
(3) Limitation of Voltage application
Minimum: 198 V Maximum: 264 V
(4) The refrigerant quantity to be charged includes the refrigerant in 7.5 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, (when it is less than 10 m, add 10 g refrigerant per meter and when it is 10 to 15 m, add 30 g refrigerant per meter.)
(5) Expressed in sound pressure level.
Notes (1) The data are measured at the following conditions.
Model SRK561CENF-L (Indoor unit)
SRC561CENF-L (Outdoor unit)
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27°C19°C35°C24°C JIS C9612, ISO-T1
Item
Model
SRK561CENF-L SRC561CENF-L
Cooling capacity
(1)
W 5000/5000
Power source 1 Phase, 220/240V, 50 Hz
Cooling input kW 2.08/2.18
Running current (Cooling) A 10.2/9.53
Inrush current A 44/48
COP (In cooling) 2.40/2.29
Noise level
(5)
dB (A) 45/45 53/54
Exterior dimensions mm
275 × 790 × 189 615 × 850 × 290 + 30
Height × Width × Depth
Color Ivory white Polar white
Net weight kg 9 52
Refrigerant equipment
RM5526GNE4 (Rotary type) × 1
Compressor types & Qty
Motor kW 1.9
Starting method Line starting
Heat exchanger Louver fins & tubing
Refrigerant control Capillary tubes
Refrigerant
(4)
kg R22 1.35
Refrigerant oil R 0.7 (BARREL FREEZE 32SAM)
Air handling equipment
Tangential fan × 1 Propeller fan × 1
Fan type & Qty
Motor W 23 40
Air flow (at High) CMM 12/12 34/34
Air filter, Qty Polypropylene net (washable) × 2
Shock & vibration absorber Cushion rubber (for compressor)
Electric heater ––
Operation control
Wireless-Remote controller
Operation switch
Room temperature control MC. Thermostat
Pilot lamp RUN (Green), TIMER (Yellow),
ECONO (Orange), HI POWER (Green)
Safety equipment
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
O.D mm (in) Liquid line: φ6.35 (1/4") Gas line: φ12.7 (1/2")
Connecting method Flare connecting
Attached length of piping Liquid line: 0.4m
Gas line : 0.35m
Insulation Necessary (Both sides)
Drain hose Connectable
Power source cord 2.5 m (3 cores with Earth)
Size × Core number 1.5 mm
2
× 3 cores (Including earth cable)
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit
Optional parts
Connection
wiring
Operation
data
(1)
Refrigerant
piping