EasyManuals Logo
Home>MrCool>Air Conditioner>DIY E Star Series

MrCool DIY E Star Series Quick Start Setup Guide

MrCool DIY E Star Series
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
STEP 3 - Continued
STEP 4 - Outside
STEP 4 - Continued
4. Snap the air handler onto the wall bracket by leaning the
top towards the wall and hooking it on the top of bracket.
Then, apply pressure to the bottom half to snap it to the
bracket.
1. Place outside condenser unit firmly on the ground or
attach it to a secure metal wall bracket or pad. A drain pipe
underneath the unit is not required unless the unit is
elevated. Please refer to the manual for more information.
2. Install the wall hole finishing cap/seal. Then, carefully
bend the piping coming out of the wall hole (from the
indoor unit) down towards the wall.
3. Remove the plastic seals from the indoor handler
refrigerant lines.
4. Carefully unroll one end of the Quick Connect® line set.
Only unroll the amount needed to connect to the indoor
handler fittings. Leave the remainder coiled.
5. Align the Quick Connect® refrigerant lines to the
matching indoor handler fittings. Tighten the first few
threads by hand.
6. Using two open-ended wrenches, or crescent
(adjustable-type) wrenches, and the image below as a
guide: place the wrenches on points marked “1” & “2,” only
turning the nut at the point marked “2.” Ensure that the
screw connector does not become crooked while working
quickly to tighten it. Tighten the connector until snug.
7. Then, tighten the connector slightly beyond that point to
apply torque to the connector. Repeat the same steps for
the second line. Please refer to the manual for information
about torque requirements for the connectors.
Minimum Clearance between
the back of unit and wall:
**Ground Installed:
12 in (30 cm)
**Bracket Installed:
6 in (15 cm)
Minimum Clearance
in front of unit:
79 in (200 cm)
Minimum Clearance
on the left side of unit:
12 in (30 cm)
Minimum Clearance
above unit:
24 in (60 cm)
Minimum Clearance
on the right side of unit:
24 in (60 cm)
1
2

Other manuals for MrCool DIY E Star Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MrCool DIY E Star Series and is the answer not in the manual?

MrCool DIY E Star Series Specifications

General IconGeneral
BrandMrCool
ModelDIY E Star Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals