TERMINAL CONNECTION
ENVIRONMENT CONDITION:
Relative Humidity
Protection Level
(AS Per Request)
Operating Temp.
0°C to 55°C
UP to 95% RH
(non-condensing)
IP-65 (Front side) As per IS/IEC
60529 : 2001
Class 0.5 (Standard)
ACCURACY:
AUXILIARY SUPPLY :
Supply voltage
Power consumption
(VA RATING)
Approx 4 VA @ 230V AC MAX
100 to 270V AC, 50/60Hz
TECHNICAL SPECIFICATION
SET/ENT, INC, DEC, RESET
Display
Key
DISPLAY & KEY :
Size
Panel Cutout
96 (H) x 96 (W) x 54 (D) mm
92 (H) x 92 (W) mm
DIMENSION :
POWER
ENERGY
Input Signal
PT Primary
CT Secondary
PT Secondary
3 Wire / 4Wire / 2Wire
CT Primary
up to 6000A (Programmable)
100V to 520kV (Programmable)
5 Amp/1 Amp selectable
100V to 520V (L-L) (Programmable)
KW Total
kW Per Phase
WH Total
PF Avg. & Per Phase
kVA Total
kVAr Total
kVA Per Phase
kVAr Per Phase
Load hours
RPM
Frequency (Hz)
No load hours
0.000 - 9999 kW
0.000 - 9999 kW
000.000 - 999999 MWh
000.000 - 999999999.999 KVAh
000.000 - 999999999.999 KVArh
0.100 - 1.000
0.000 - 9999 kVA
0.000 - 9999 kVAr
0.000 - 9999 kVA
0.000 - 9999 kVAr
45.00 - 60.00 Hz
9999.59 Hrs/Min.
9999.59 Hrs/Min.
3600 RPM @ 60 Hz & 2 pole
Vah Total
Varh Total
6 Digit, 7 Seg 0.40”,RED LED
4 Digit, 3 Line 7 Seg 0.39”,RED
Upper
Lower
Page-1
AVH-14 Manual
MULTI FUNCTION METER
PROGRAM, VAF, POWER, ENERGY
Display
Key
DISPLAY & KEY :
Size
Panel Cutout
96 (H) x 96 (W) x 54 (D) mm
92 (H) x 92 (W) mm
DIMENSION :
POWER
ENERGY
Input Signal
PT Primary
CT Secondary
PT Secondary
3Ø 3 Wire / 3Ø 4Wire / 1Ø 2Wire
CT Primary
up to 6000A (Programmable)
100V to 520kV (Programmable)
5 Amp/1 Amp selectable
100V to 520V (L-L) (Programmable)
KW Total
kW Per Phase
WH Total
PF Avg. & Per Phase
kVA Total
kVAr Total
kVA Per Phase
kVAr Per Phase
Load hours
RPM
Frequency (Hz)
No load hours
0.000 - 9999 MW
0.000 - 9999 MW
000.000 - 99999999 MWh
000.000 - 99999999 MVAh
000.000 - 99999999 MVArh
0.100 - 1.000
0.000 - 9999 MVA
0.000 - 9999 MVAr
0.000 - 9999 MVA
0.000 - 9999 MVAr
45.00 - 60.00 Hz
9999.59 Hrs/Min.
9999.59 Hrs/Min.
3600 RPM @ 60 Hz & 2 pole
Vah Total
Varh Total
8 Digit, 7 Seg 0.40”,RED LED
4 Digit, 3 Line 7 Seg 0.40”,RED
Upper
Lower
AVH 14
VAF
PRG
P
E
W hk
MAX
k
var
k
W
k
VA
S1 S1 S1 S2S2S2
L1
L2
L3
L N
1 2 3 4
7
8
9
10
5
6
20
19 18
17
14
13
12
11
16 15
!
Made in India
100
270V AC
~
50/60 Hz
4VA
CAT III
VL1 VL2
VL3
N
Current: 10mA To 5A AC
Voltage (L-L) : 35-520V AC
(L-N) : 20-300V AC
Accuracy Class: 0.5
System: 1Ph-2W/3Ph-3W/
3Ph-4W
www.multispanindia.com
AVH 14
Primary PT : 100V to 520KV
Secondary PT : 100V to 520V
Primary CT: Up to 6000A AC
Secondary CT: By 5A/1A AC
+ -