- A 51 ・ -
logo_Q0650_forGraphic
071004_Gdesign_ito
VBA21001-R.3753.A
7-3. Pixel defect compensation - white point
・Click "Start".
・Setting conditions are displayed.
・Cap the camera with the body cap or lens cap to shield light from the mount.
・Click "OK".
・The adjustment starts. When it is completed, "OK" is displayed.
・Click "OK".
7-4. Getting of reference values
Obtain sensitivity reference value:
・Select "OBTAIN REFERENCE VALUE." of the menu on screen.
・Click "Start".
・Setting conditions are displayed.
・Attach the tool lens (Aperture F8) and ND lter (ND8×1 + ND4×1).
・Get the camera closest to the center of the illuminated surface of the color viewer.
・Click "OK".
・The adjustment starts. When it is completed, "OK" is displayed.
・Click "OK".
・Click "Next".
Obtain sensitivity ratio reference value:
・Click "Start".
・Setting conditions are displayed.
・Attach the tool lens (Aperture F5.6) (without lter).
・Get the camera closest to the center of the illuminated surface of the shutter tester (LV9).
・Click "OK".
・The adjustment starts. When it is completed, the next setting conditions are displayed.
・Attach the tool lens (Aperture F5.6) and ND lter (ND8×1).
・Get the camera closest to the center of the illuminated surface of the color viewer.
・Click "OK".
・The adjustment starts. When it is completed, "OK" is displayed.
・Click "OK".
※ After the acquisition of reference values is completed, the sensitivity and sensitivity ratio reference values
are stored in the standard setting le (D60BSD.DAT).
※ After this procedure, when the shooting image adjustment is made, the sensitivity and sensitivity ratio that
have been calculated this time will be used.
※ Calculate the sensitivity and sensitivity ratio reference values once in about every 3 months, and when the
uorescent of the color viewer is replaced.