OLED User Interface
31
Part 1128351_02
E 2020 Nordson Corporation
Managing System Air Pressure
The following table details the default and optional pressure monitoring and
adjusting options.
Pressure Type What you can do…
Manual Pressure Adjust
(Default)
Manually adjust the system pressure using a 6mm Hex wrench. Use the gauge
to help define system air pressure you want.
Digital Pressure
monitoring
(Optional - requires
additional equipment)
Same as the manual Pressure Adjust, but you can also view (only) the system
air pressure from the Home screen.
Enable/Disable the controller monitoring the minimum and maximum absolute
system air pressure before causing an alarm.
Electrical Pressure
Adjust
(Optional - requires
additional equipment)
From the Home screen, you can view and adjust the system air pressure.
Define minimum and maximum air pressure set points.
Enable/Disable the controller monitoring the minimum and maximum system air
pressure thresholds from set point before causing an alarm.
Manually Adjusting System Air Pressure
S Using a 6mm Hex wrench, turn clockwise to increase pressure and
counterclockwise to decrease pressure to best suit your production
requirements. Refer to Figure 6.
Picture shown with optional Fill System
Optional pressure gauge
Manual pressure adjustment
Figure 6 Manual Pressure Adjustment