18
B6EM
A-CABINET
SWITCH SETTINGS
0 = OFF, 1 = ON
COOLING OR HEATING AIRFLOW (CFM)
DRY COIL ESP
1/5 2/6 3/7 4/8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0 0 0 0 585 550 520 460 420 405
1 0 0 0 710 670 650 610 560 530 475 440
0 1 0 0 845 790 765 715 680 655 625 580
1 1 0 0 890 865 840 785 760 710 680 655
0 0 1 0 955 925 900 850 825 790 770 720
1 0 1 0 1030 995 975 940 910 870 840 815
0 1 1 0 1115 1085 1060 1020 995 965 925 905
1 1 1 0 1155 1130 1095 1070 1040 1010 985 950
0 0 0 1 1200 1175 1145 1110 1085 1060 1025 1000
1 0 0 1 1240 1215 1195 1170 1140 1110 1080 1060
0 1 0 1 1320 1290 1265 1240 1215 1185 1160 1130
1 1 0 1 1355 1330 1305 1280 1255 1220 1200 1175
0 0 1 1 1405 1375 1345 1325 1295 1275 1250 1210
1 0 1 1 1440 1415 1385 1355 1325 1290 1255 1215
0 1 1 1 1465 1425 1390 1355 1320 1290 1260 1215
1 1 1 1 1465 1425 1390 1355 1320 1290 1260 1215
B6EM
B-CABINET
SWITCH SETTINGS
0 = OFF, 1 = ON
COOLING OR HEATING AIRFLOW (CFM)
DRY COIL ESP
1/5 2/6 3/7 4/8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0 0 0 0 600 550 430 390
1 0 0 0 660 610 540 460 425
0 1 0 0 830 750 695 640 580 520
1 1 0 0 860 825 765 690 630 600 525 485
0 0 1 0 935 895 835 790 710 655 620 585
1 0 1 0 1045 975 920 875 830 795 720 685
0 1 1 0 1095 1040 995 950 900 850 805 750
1 1 1 0 1155 1105 1060 1010 965 920 870 825
0 0 0 1 1230 1185 1140 1090 1045 1010 965 920
1 0 0 1 1285 1260 1210 1165 1125 1080 1040 1010
0 1 0 1 1330 1290 1245 1205 1170 1125 1085 1045
1 1 0 1 1395 1365 1315 1275 1235 1205 1160 1130
0 0 1 1 1450 1405 1375 1335 1295 1260 1220 1180
1 0 1 1 1490 1450 1410 1385 1340 1300 1270 1230
0 1 1 1
1530 1485 1460 1425 1380 1350 1310 1280
1 1 1 1 1530 1490 1465 1425 1390 1350 1310 1285
B6EM
C-CABINET
SWITCH SETTINGS
0 = OFF, 1 = ON
COOLING OR HEATING AIRFLOW (CFM)
DRY COIL ESP
1/5 2/6 3/7 4/8 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0 0 0 0 710 580 395
1 0 0 0 830 690 675 530 505
0 1 0 0 930 875 710 665 560 530
1 1 0 0 1065 1015 900 840 800 705 665 635
0 0 1 0 1185 1115 1010 960 925 875 830 745
1 0 1 0 1275 1220 1175 1120 1060 970 930 890
0 1 1 0 1365 1350 1255 1200 1150 1105 1060 1025
1 1 1 0 1480 1430 1370 1325 1265 1225 1185 1140
0 0 0 1 1560 1535 1485 1430 1375 1335 1285 1240
1 0 0 1 1650 1600 1545 1500 1450 1405 1360 1305
0 1 0 1 1730 1685 1660 1610 1570 1520 1470 1420
1 1 0 1 1785 1740 1695 1645 1615 1545 1510 1470
0 0 1 1 1865 1820 1785 1750 1695 1655 1605 1560
1 0 1 1 1920 1890 1850 1805 1765 1715 1675 1640
0 1 1 1 2010 1965 1960 1900 1850 1810 1775 1730
1 1 1 1 2065 2020 1985 1955 1915 1880 1840 1810
NOTE: When matched with two-stage outdoor units, the airflow on low (Y1 or W1) input will be 70% of the values shown in this table.
Table 6. B6EM (FSHE) Airflow Data