68X415307 Rev. 1 Oct 07
Integrated Instruction Manual
WP 600 Series Meters
pH 600/ 610/ 620, COND 600/610, DO 600,
PC 650, PD 650, CD 650, PCD 650
2
Table of Contents
Default Chapter
5
Table of Contents
5
General Guide
9
Overview - for All Meters
11
About the Meters
11
Display Overview
11
Key Functions
11
Inserting Batteries
12
Inserting Batteries for the First Time
12
Changing Batteries Subsequently
12
Attaching the Belt
13
Connecting Peripherals
14
Probes (Ph/Conductivity/Do)
14
Protective Rubber Boot
15
System Setup
15
System Settings
15
Setup Mode - for All Meters
22
About Setup Mode
22
Accessing Setup Mode (no Password Protection Enabled)
22
Accessing Setup Mode When Password Protection Enabled
23
Modifying Setup Parameters
24
Calibration Mode - for All Meters
26
About Calibration
26
About Conductivity/ Resistivity/ TDS/ Salinity Calibration
26
Prepare the Meter for Calibration
26
Accessing Calibration Mode
28
Accessing Calibration Mode When Password Protection Enabled
28
Measurement Mode - for All Meters
29
About Measurement Mode
29
Accessing Functions
30
Taking Measurements
31
Prepare the Meter for Measurement
31
Taking a Reading
31
Stable Reading Indicator
31
Holding a Reading
32
Automatic Temperature Compensation (ATC)
32
Manual Temperature Compensation (MTC)
32
Alarm Set Point (for Ph/Conductivity/Do)
33
Calibration Due (CAL-DUE) Indicator (for Ph/Conductivity/Do)
33
Temperature
35
Temperature Setup
37
Temperature Calibration
37
About Temperature Calibration
37
Temperature Calibration for ATC Mode
38
Temperature Calibration for MTC Mode
39
Temperature Measurement
39
Ph Setup
43
Ph Calibration
44
About Ph Calibration
44
Ph Buffer Group for Calibration and Auto-Recognition
45
Ph Calibration Points
45
Ph Calibration with a Standard Buffer
45
Ph Calibration with a User-Defined Buffer
47
Calibration Report
48
Average Slope Indicator of Ph Probe
49
Ph Measurement Mode
50
Resolution of Ph Reading
50
Indicators in Ph Measurement Screen
50
MV Setup Mode
53
MV Calibration Mode
53
MV Calibration Report
54
MV Measurement Mode
54
Indicators in MV Measurement Mode
54
Ion
57
Ion Setup
59
Ion Calibration Mode
59
About Ion Calibration
59
Calibration Report
61
To View Calibration Report
61
Ion Measurement Mode
62
Changing Unit of Measurement
62
Indicators in Ion Measurement Mode
62
Conductivity
63
Conductivity Setup
65
Conductivity Calibration Mode
67
Conductivity Calibration Points
67
Cell Constant
67
Normalization Temperature ( ° C)
67
Linear Temperature Coefficient
67
Pure Water Coefficient
68
To Begin Calibration
68
Manual Calibration
69
Automatic Calibration (for Conductivity Calibration)
69
Calibration Report
71
Conductivity Measurement Mode
72
Indicators in Conductivity Measurement Screen
72
Tds
73
TDS Setup
75
TDS Calibration Mode
77
TDS Calibration Report
78
TDS Measurement Mode
78
Indicators in TDS Measurement Mode
78
Salinity
80
Salinity Setup
82
Salinity Calibration Mode
83
Salinity Calibration Report
84
To View Salinity Report
84
Salinity Measurement Mode
85
Indicators in Salinity Measurement Mode
85
Resistivity
87
Resistivity Setup
89
Resistivity Calibration Mode
90
Resistivity Calibration Report
91
To View Resistivity Report
92
Resistivity Measurement Mode
92
Indicators in Resistivity Measurement Mode
92
Dissolved Oxygen
95
PART a - % Saturation Mode
97
O2 % - DO Saturation Setup
97
DO Calibration in % Saturation Mode (with ATC)
99
About DO(%) and DO (Mg/L) Calibration
99
To Calibrate 100% Saturation
99
To Calibrate 0% Saturation
101
DO Calibration Report
102
To View Calibration Report
102
Saturation Offset Adjustment
103
Set Barometer Pressure Range and Barometric Pressure Units
103
Pressure Compensation
103
Percentage Saturation (%) Measurement Mode
104
Indicators in Percentage Saturation Measurement Mode
104
PART B - Concentration (Mg/L) (Ppm) Mode
105
O2 Mg/L (Ppm) - DO Concentration Setup
105
DO Calibration in Mg/L or Ppm Concentration Mode
107
Concentration Calibration Report
108
To View Concentration Report
108
Set Salinity
109
Auto Salinity Compensation
109
Concentration in Measurement Mode
109
Indicators in Concentration Measurement Screen
109
Transferring and Printing Data
111
Cybercomm 600 Data Acquisition Software
111
Working with Memory Functions - Auto Data Logging
111
Logging Data Automatically in the Meter's Memory
111
Storing a Current Measurement (in Irda and LED Print Mode: Applicable to All Modes)
112
Viewing Stored Data
112
Transferring Stored Data to the Computer (Cybercomm) through Irda
112
Transferring Stored Data to a PC Not Equipped with Infrared Receiver
114
Transferring Stored Data to a PC Using an USB/ Irda Dongle
115
Technical Specifications
116
Accessories
120
Appendix
122
Conductivity Theory
122
Calculating TDS Conversion Factor
124
Calculating Temperature Coefficients
124
Dissolved Oxygen Probe
125
Dissolved Oxygen Principle
125
Probe Care
125
Membrane Housing Replacement
126
Membrane/O-Ring Replacement (Optional Procedure)
126
Electrolyte Solution
127
General Information
128
Warranty
128
Return of Goods
128
Guidelines for Returning Unit for Repair
128
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Oakton pH 610 and is the answer not in the manual?
Ask a question
Oakton pH 610 Specifications
General
Brand
Oakton
Model
pH 610
Category
Measuring Instruments
Language
English
Related product manuals
Oakton pH 5+
24 pages
Oakton PC 700
28 pages
Oakton WP PCD 650
120 pages
Oakton 700 Series
4 pages
Oakton Ion 510 Series
30 pages
Oakton CON 11
80 pages
Oakton Bench 2700 Series
8 pages
Oakton T100WL
20 pages