EasyManuals Logo
Home>Omron>Blood Pressure Monitor>M1 Basic HEM-7121J-LAF

Omron M1 Basic HEM-7121J-LAF User Manual

Omron M1 Basic HEM-7121J-LAF
9 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
EN FR
Introduction
Important Safety Information
1. Know Your Monitor
2. Preparation
3. Using Your Monitor
4. Using Memory Function
5. Other Settings
6. Error Messages and Troubleshooting
7. Maintenance
8. Optional Medical Accessories
9. Specifications
10. Limited Warranty
11. Guidance and Manufacturers Declaration
Thank you for purchasing the OMRON Automatic Upper Arm Blood Pressure Monitor. This
blood pressure monitor uses the oscillometric method of blood pressure measurement. This
means this monitor detects your blood movement through your brachial artery and converts
the movements into a digital reading.
Safety Instructions
This instruction manual provides you with important information about the OMRON
Automatic Upper Arm Blood Pressure Monitor.
To e n s u r e t h e s a f e a n d p roper u s e o f t h i s m o n i t o r, R E A D a n d U N D E R STA ND a l l o f t h e s e
instructions. If you do not understand these instructions or have any questions,
contact your OMRON retail outlet or distributor before attempting to use this monitor.
For specific information about your own blood pressure, consult with your physician.
Intended Use
This device is a digital monitor intended for use in measuring blood pressure and pulse rate
in adult patient population. It is mainly designed for general household use.
Receiving and Inspection
Remove this monitor from the packaging and inspect for damage. If this monitor is
damaged, DO NOT USE and consult with your OMRON retail outlet or distributor.
Read the Important Safety Information in this instruction manual before using this
monitor.
Follow this instruction manual thoroughly for your safety.
Keep for future reference. For specific information about your own blood pressure,
CONSULT WITH YOUR PHYSICIAN.
Warning
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
•DO NOT use this monitor on infants, toddlers, children or persons who cannot
express themselves.
•DO NOT adjust medication based on readings from this blood pressure monitor.
Take medication as prescribed by your physician. ONLY a physician is qualified to
diagnose and treat high blood pressure.
DO NOT use this monitor on an injured arm or an arm under medical treatment.
•DO NOT apply the arm cuff on your arm while on an intravenous drip or blood
transfusion.
•DO NOT use this monitor in areas containing high frequency (HF) surgical
equipment, magnetic resonance imaging (MRI) equipment, computerized
tomography (CT) scanners. This may result in incorrect operation of the monitor
and/or cause an inaccurate reading.
DO NOT use this monitor in oxygen rich environments or near flammable gas.
•Consult with your physician before using this monitor if you have common
arrhythmias such as atrial or ventricular premature beats or atrial fibrillation;
arterial sclerosis; poor perfusion; diabetes; pregnancy; pre-eclampsia or renal
disease. NOTE that any of these conditions in addition to patient motion, trembling,
or shivering may affect the measurement reading.
•NEVER diagnose or treat yourself based on your readings. ALWAYS consult with
your physician.
•To help avoid strangulation, keep the air tube and AC adapter cable away from
infants, toddlers and children.
•This product contains small parts that may cause a choking hazard if swallowed by
infants, toddlers and children.
AC Adapter (optional accessory) Handling and Usage
•DO NOT use the AC adapter if this monitor or the AC adapter cable is damaged. If
this monitor or the cable is damaged, turn off the power and unplug the AC adapter
immediately.
•Plug the AC adapter into the appropriate voltage outlet. DO NOT use in a multi-
outlet plug.
•NEVER plug in or unplug the AC adapter from the electric outlet with wet hands.
DO NOT disassemble or attempt to repair the AC adapter.
Battery Handling and Usage
•Keep batteries out of the reach of infants, toddlers and children.
Caution
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury to the user or patient, or
cause damage to the equipment or other property.
•Stop using this monitor and consult with your physician if you experience skin
irritation or discomfort.
•Consult with your physician before using this monitor on an arm where
intravascular access or therapy, or an arteriovenous (A-V) shunt, is present
because of temporary interference to blood flow and could result in injury.
•Consult with your physician before using this monitor if you have had a
mastectomy.
•Consult with your physician before using this monitor if you have severe blood
flow problems or blood disorders as cuff inflation can cause bruising.
•DO NOT take measurements more often than necessary because bruising, due to
blood flow interference, may occur.
•ONLY inflate the arm cuff when it is applied on your upper arm.
Automatic Upper Arm Blood
Pressure Monitor
M1 Basic (HEM-7121J-LAF)
Instruction Manual
IM-HEM-7121J-LAF-EN-02-01/2020
3275342-0B
Table of Contents
Introduction
Important Safety Information
•Remove the arm cuff if it does not start deflating during a measurement.
•DO NOT use this monitor for any purpose other than measuring blood pressure.
•During measurement, make sure that no mobile device or any other electrical
device that emit electromagnetic fields is within 30 cm of this monitor. This may
result in incorrect operation of the monitor and/or cause an inaccurate reading.
•DO NOT disassemble or attempt to repair this monitor or other components. This
may cause an inaccurate reading.
•DO NOT use in a location where there is moisture or a risk of water splashing this
monitor. This may damage this monitor.
•DO NOT use this monitor in a moving vehicle such as in a car or on an aircraft.
•DO NOT drop or subject this monitor to strong shocks or vibrations.
•DO NOT use this monitor in places with high or low humidity or high or low
temperatures. Refer to section 9.
•During measurement, observe the arm to ensure that the monitor is not causing
prolonged impairment to blood circulation.
DO NOT use this monitor in high-use environments such as medical clinics or
physician offices.
•DO NOT use this monitor with other medical electrical (ME) equipment
simultaneously. This may result in incorrect operation and/or cause an inaccurate
reading.
•Avoid bathing, drinking alcohol or caffeine, smoking, exercising and eating for at
least 30 minutes before taking a measurement.
•Rest for at least 5 minutes before taking a measurement.
•Remove tight-fitting or thick clothing from your arm while taking a measurement.
•Remain still and DO NOT talk while taking a measurement.
•ONLY use the arm cuff on persons whose arm circumference is within the specified
range of the cuff.
•Ensure that this monitor has acclimated to room temperature before taking a
measurement. Taking a measurement after an extreme temperature change could
lead to an inaccurate reading. OMRON recommends waiting for approximately
2hours for the monitor to warm up or cool down when the monitor is used in an
environment within the temperature specified as operating conditions after it is
stored either at the maximum or at the minimum storage temperature. For
additional information on operating and storage/ transport temperature, refer to
section 9.
•DO NOT use this monitor after the durable period has ended. Refer to section 9.
•DO NOT crease the arm cuff or the air tube excessively.
•DO NOT fold or kink the air tube while taking a measurement. This may cause an
injury by interrupting blood flow.
•To unplug the air plug, pull on the plastic air plug at the base of the tube, not the
tube itself.
•ONLY use the AC adapter, arm cuff, batteries and accessories specified for this
monitor. Use of unsupported AC adapters, arm cuffs and batteries may damage
and/or may be hazardous to this monitor.
•ONLY use the approved arm cuff for this monitor. Use of other arm cuffs may result
in incorrect readings.
•Inflating to a higher pressure than necessary may result in bruising of the arm
where the cuff is applied. NOTE: refer to “If your systolic pressure is more than
210 mmHg” in section 3 for additional information.
•Read and follow the Correct Disposal of This Product in section 11 when
disposing of the device and any used accessories or optional parts.
AC Adapter (optional accessory) Handling and Usage
•Fully insert the AC adapter into the outlet.
•When unplugging the AC adapter from the outlet, be sure to safely pull from the AC
adapter. DO NOT pull from the AC adapter cable.
•When handling the AC adapter cable:
Do not damage it. / Do not break it. / Do not tamper with it.
DO NOT pinch it. / Do not forcibly bend or pull it. / Do not twist it.
DO NOT use it if it is gathered in a bundle.
DO NOT place it under heavy objects.
•Wipe any dust off of the AC adapter.
•Unplug the AC adapter when not in use.
•Unplug the AC adapter before cleaning this monitor.
Battery Handling and Usage
•DO NOT insert batteries with their polarities incorrectly aligned.
•ONLY use 4 AA batteries with this monitor.
DO NOT use other types of batteries. DO NOT use new and used batteries together.
DO NOT use different brands of batteries together.
•Remove batteries if this monitor will not be used for a long period of time.
•If battery fluid should get in your eyes, immediately rinse with plenty of clean water.
Consult with your physician immediately.
•If battery fluid should get on your skin, wash your skin immediately with plenty of
clean, lukewarm water. If irritation, injury or pain persists, consult with your
physician.
•DO NOT use batteries after their expiration date.
•Periodically check batteries to ensure they are in good working condition.
1.1 Contents
Monitor, arm cuff, 4 AA batteries, instruction manual
1.2 Monitor
1. Know Your Monitor
b
a
c
e
d
Display
[START/STOP] button
Battery compartment
AC adapter jack
Air jack
a
b
c
d
e
f
g
h
Arm cuff
(Arm circumference 22 - 42 cm)
Air plug
Air tube
f
g
h
1.3 Display and Symbols
1.4 Classification of BP (Blood Pressure)
2018 ESH/ESC* Guidelines for the management of arterial hypertension
Definitions of hypertension by office and home blood pressure levels
These ranges are from statistical values for blood pressure.
*European Society of Hypertension (ESH) and European Society of Cardiology (ESC).
Warning
•NEVER diagnose or treat yourself based on your readings. ALWAYS consult with your
physician.
2.1 Installing Batteries
1. Push down on the hook of the battery
cover and pull downward.
2. Insert 4 “AA” batteries as indicated in
the battery compartment.
3. Close the battery cover.
Note
•When the symbol flashes on the display, it is recommended you replace batteries.
•To replace batteries, turn your monitor off and remove all batteries. Then replace with
4new batteries at the same time.
•Replacing batteries will not delete previous readings.
•The supplied batteries may have a shorter life than new batteries.
•Disposal of used batteries should be carried out in accordance with local regulations.
2.2 Blood Pressure Measurement Tips
To h e l p e n s u r e a n a c c u r a t e r e a d i n g, follow t h ese d ire c t i o n s:
•Stress raises blood pressure. Avoid taking measurements during stressful times.
•Measurements should be taken in a quiet place.
•It is important to take measurements at same times each day. Taking measurements in
the morning and in the evening is recommended.
•Remember to have a record of your blood pressure and pulse readings for your physician.
A single measurement does not provide an accurate indication of your true blood
pressure. Please use the Blood Pressure Diary to keep records of several readings over a
certain period of time. To download PDF files of the diary, visit
www.omron-healthcare.com.
Caution
•Avoid bathing, drinking alcohol or caffeine, smoking, exercising and eating for at least
30 minutes before taking a measurement.
•Rest for at least 5 minutes before taking a measurement.
A
B
C
D
E
F
G
A
Systolic blood pressure reading
B
Diastolic blood pressure reading
C
Deflation symbol
Appears during cuff deflation.
D
Heartbeat symbol
Flashes during measurement.
E
Memory symbol
Appears when viewing readings stored in the memory.
F
Low battery symbol
Flashes when batteries are low.
Depleted battery symbol
Appears when batteries are depleted.
G
Pulse display
Pulse rate appears after the measurement.
When pressing the [Memory] button, the memory number appears for approximately
one second before the pulse rate appears on the display.
Office Home
Systolic Blood Pressure 140 mmHg 135 mmHg
Diastolic Blood Pressure 90 mmHg 85 mmHg
2. Preparation
2.3 Applying the Arm Cuff
•The following steps are for applying the arm cuff to your left arm. When you take a
measurement on your right arm, follow the cuff wrap instructions for a right arm use
mentioned under To take a measurement on your right arm” located at the end of this
sub-section.
•The blood pressure can differ between the right arm and the left arm, and the measured
blood pressure readings can be different. OMRON recommends to always use the same
arm for measurement. If the readings between both arms differ substantially, check with
your physician to determine as to which arm to use for your measurements.
Caution
•Remove tight-fitting or thick clothing from your arm while taking a measurement.
1. Plug the arm cuff into your monitor by inserting the air
plug into the air jack securely.
2. Place your hand through the cuff loop. Pull the cuff
until it reaches your upper left arm.
Note
•The bottom edge of the arm cuff should be 1 to 2 cm
above the inside elbow. The air tube is on the inside
of your arm and aligned with your middle finger.
3. Make sure that the air tube is positioned on the
inside of your arm and wrap the cuff securely, so
it can not move around your arm.
To take a measurement on your right arm
When you take a measurement on your right arm, the
air tube should run along the side of your elbow, along
the bottom of your arm. Be careful not to rest your arm
on the air tube.
2.4 Sitting Correctly
To ta k e a m ea s u re men t , y o u n e ed t o b e r e la x e d a n d
comfortably seated in a room with a comfortable
temperature.
Place your arm on the table.
•Sit in a comfortable chair with your back and arm
supported.
•Keep your feet flat and your legs uncrossed.
The arm cuff should be placed on your arm at the
same level as your heart, with the arm resting
comfortably on a table.
3.1 Taking a Measurement
Caution
DO NOT use this monitor with other medical electrical (ME) equipment simultaneously.
This may result in incorrect operation and/or cause an inaccurate reading.
•Remain still and do not talk while taking a measurement.
1. Press the [START/STOP] button.
All symbols appear on the display before starting the measurement.
The battery symbol that is displayed at this time do not indicate the battery level. They
are displayed merely for confirmation.
2. Remain still and do not talk until the entire measurement process is
complete.
The symbol flashes at every heartbeat.
After your monitor has detected your blood pressure and pulse rate, the cuff
automatically deflates. Your blood pressure and pulse rate are displayed.
3. Press the [START/STOP] button to turn your monitor off.
Note
•Wait 2 - 3 minutes between measurements. The wait time allows the arteries to
decompress and return to their pre-measurement state.
You may need t o increase the wait time depending on your individual physiological
characteristics.
If your systolic pressure is more than 210 mmHg
If your systolic pressure is more than 210 mmHg, take a measurement
manually.
After the arm cuff starts to inflate, press and hold the [START/STOP] button
until the monitor inflates 30 to 40 mmHg higher than your expected systolic
pressure.
Note
•Do not inflate above 299 mmHg.
Caution
•Inflating to a higher pressure than necessary may result in bruising of the arm where the
cuff is applied.
3. Using Your Monitor
START INFLATING
COMPLETED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Basic HEM-7121J-LAF and is the answer not in the manual?

Omron M1 Basic HEM-7121J-LAF Specifications

General IconGeneral
BrandOmron
ModelM1 Basic HEM-7121J-LAF
CategoryBlood Pressure Monitor
LanguageEnglish

Related product manuals