Congratulations on your purchase of a quality Orion 2"
Crayford focuser. This focuser is intended for use with New-
tonian reectors. If you do not have a Newtonian reector, the
focuser may not be appropriate for your telescope.
Crayford focusers generally perform better than rack-and-pin-
ion models because the design reduces “focus shift”. Focus
shift is when an image moves position in the eyepiece when
it is being focused. This is very hard to eliminate in rack-and-
pinion focusers due to slight gear and tolerance imperfec-
tions which cause the drawtube to move slightly left or right
when focusing. For the Crayford design, the drawtube is
constantly tensioned (by the focusing shaft and four “roller
bearings”) so the drawtube cannot move perpendicular to the
desired motion.
Installation
This focuser was designed to be a “drop-in” replacement for
the 2" rack-and-pinion focuser that comes standard on Orion
reectors greater than 6" in aperture, including IntelliScope
and Classic Dobsonians. If you have one of these tele-
scopes, installing the 2" Crayford will be extremely easy. You
will need a Phillips head screwdriver and an adjustable cres-
cent wrench or pliers. Use the procedure outlined below:
Note: The SkyQuest XT8 Classic, or any size Classic style
XT Dobsonian manufactured before June 2002, are not
compatible with this focuser as a “drop-in” replacement.
If you have one of these telescopes please skip to the
paragraph following step 7.
1. Position your Newtonian reector optical tube so it is hori-
zontal. This will prevent any screws or nuts from falling
onto the primary mirror.
2. From the inside of the tube, secure one of the four focuser
securing nuts with the wrench or pliers.
3. Use the screwdriver to completely unthread the focuser
attachment screw from the securing nut currently being
held by the wrench or pliers.
4. Repeat this for the other three nut and screw pairs.
5. Remove the 2" rack-and-pinion focuser from the tube.
6. Place the 2" Crayford focuser where the rack-and-pinion
focuser was previously. Orient the focuser the same as
the removed one was. The through holes in the base of
the focuser should line up with the holes in the telescope
tube.
7. Reinstall the four screw and nut pairs using the wrench or
pliers and screwdriver. Tighten the screws rmly.
IN 300 Rev G 11/09
Orion 2" Crayford Focuser for
Newtonian Reflectors
#13039
Figure 1. The Orion 2" Crayford focuser for Newtonian reectors.
1.25" adapter
Focusing tension
adjustment set screw
Collimation screws
Focus wheel
Focus lock thumbscrew
Drawtube
Focusing shaft
Corporate Offices: 89 Hangar Way, Watsonville CA 95076 - USA
Toll Free USA & Canada: (800) 447-1001
International: +1(831) 763-7000
Customer Support: support@telescope.com
Copyright © 2021 Orion Telescopes & Binoculars. All Rights Reserved. No part of this product instruction or any of its contents
may be reproduced, copied, modied or adapted, without the prior written consent of Orion Telescopes & Binoculars.
AN EMPLOYEE-OWNED COMPANY
INSTRUCTION MANUAL

Other manuals for Orion 13039

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Orion 13039 and is the answer not in the manual?

Orion 13039 Specifications

General IconGeneral
BrandOrion
Model13039
CategoryAccessories
LanguageEnglish

Related product manuals