52
Press the MODE
key 5 times.
Press the
Jog switch.
Press the
Jog switch.
Press the
Jog switch.
Press the MODE key
3 times or keep it pressed
for 2 sec. or more.
When Adjust Lock is ON,
in the MODE indicator / ADJ
will not light up.
Turn the Jog
switch.
Turn the Jog switch
5 times toward
the ‘
’ direction.
Turn the Jog switch
once toward
the ‘’ direction.
The digital display will quickly
blink 3 times to confirm the setting.
The digital display will quickly
blink 3 times to confirm the setting.
9-3. Adjust Lock Setting Function
This function allows the selection of whether the ‘threshold value fine adjustment mode’ is enabled (Adjustment
Lock OFF) or disabled (Adjustment Lock ON) in RUN mode (normal sensing operation).
When set to Adjust Lock OFF, the threshold value can be adjusted directly in ‘RUN mode’ (normal sensing
operation).
1 Press the [MODE key] 5 times to select ‘PRO mode’.
2
Turn the [Jog switch] 5 times toward the ‘’ direction, to
select ‘PRO5 mode’.
3 Press the [Jog switch] to enter the ‘code setting’ state.
4
Turn the [Jog switch] once toward the ‘’ direction, to enter
the ‘adjust lock setting’ state.
5 If the [Jog switch] is pressed, the current setting will be
displayed.
* The factory setting is ‘ ’.
6 If the [Jog switch] is turned, the digital display will blink.
Select either ‘ ’ or ‘ ’.
If ‘ ’ is selected, operation of the threshold value fine
adjustment is permitted during ‘RUN mode’.
7 If the [Jog switch] is pressed, the digital display will quickly
blink 3 times, confirming the setting.
8 Press the [MODE key] 3 times or keep it pressed for 2 sec.
or more, the amplifier will return to ‘RUN mode’ (normal
sensing operation).