2
Bulletin MSG30-8302-INST
Marketing information
Parker Hannifin
Pump & Motor Division Europe
Trollhättan, Sweden
Fixed and Variable Motors
Series F11/F12 and V12/V14/T12
GENERAL INFORMATION
The sensor consists of a ferrostat differential (Dual
Channel) speed sensor and a seal nut. The sensor
installs in a threaded hole in the F12 , V12, V14 or T12
bearing housing, and in the F11 barrel housing. The
sensor output is a 2 phase shifted square wave signal
within a frequency rang of 0 Hz to 15 kHz. The sensor
detects both speed and direction of rotation. The sen-
sor withstands high as well as low temperatures and is
highly moisture protected (IP68).
TECHNICAL DATA
Power supply 10V to 30V protected against
reverse polarity.
Current Max 20 mA.
consumption
(without load)
Signal output - 2 phase shifted square wave
signals;
- Open collector outputs with 10
Kohm pull-up, Imax = -20 mA.
Frequency Min 0 Hz max 15 kHz
Insulation Housing and electronics
galvanically separated
(500V/50Hz/1 min)
Operating -40 to +125 °C
temperature [-40 to +255 °F]
Protection class IP68 (DIN 40050)
Sensor head Max 25 bar
pressure [360 psi]
Weight 0.15 kg
(incl. cable) [0.33 lb]
Sensing distance 0.1 to 2.0 mm; 1.0 recom.
[0.004 to 0.08 in; 0.04 recom.]
Transistor NPN
Amplifier variant Variant; .02 SHW
Output 1: Speed
Output 2: Speed
Output type: Open Col.
CABLE
Material PUR casting
Length 1.0 m
No. of wires 4 (plus screen; transparent)
Wire area 4 x 0.34 mm²
Screen Stranded metal net
(insulated from housing)
Bending radius Min 25 mm [1 in]
Frame Size
No. of pulses/rev.
F11-6, -10, -12, -14, -19
F12 (30-125)
F12 (152-182)
F12-250 Up to serial no. 201602230409
F12-250 From serial no. 201602230410
V12/V14 (ISO, SAE and Cartridge)
T12-060 and V12 -060 Cartridge
5
35
40
64
36
36
9
NOTE: Screen must be connected to
0 V (zero volt) power supply.
NOTE: The outputs are short circuit
proof and protected against
reverse polarity.