EasyManuals Logo
Home>PICO>Measuring Instruments>TA167

PICO TA167 User Manual

PICO TA167
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TA167
AC / DC
CURRENT PROBE
User’s Guide
SAFETY
The following symbols appear on the product:
Attention! Refer to Manual
.
Application around and removal from
UNINSULATED HAZARDOUS LIVE conductors is
permitted.
Double/Reinforced Insulation
.
Complies with the relevant European standards
.
Do not dispose of this product as unsorted
municipal waste. Contact a qualified recycler for
disposal.
To avoid electric shock:
Use caution during installation and use of this product; high
voltages and currents may be present in the circuit under
test.
This product must be used only by qualified personnel
practicing applicable safety precautions.
Do not use the product if damaged.
Always connect the probe to the scope device before
installing it around the conductor.
Do not hold the probe anywhere beyond the tactile barrier:
see Fig. 1.
SPECIFICATION
Electrical data
(All accuracies stated at 23 °C ± 1 °C)
Nominal current ............... 200 / 2000 A AC peak or DC
Measuring range (s) .......... 200 / 2000 A
Overload capacity ............. 2200 A (60 s)
Output sensitivity .............. 10 / 1 mV/A
Accuracy
1)
(0 – 200/1500 A) ± 1% of rdg ± 100 / ± 500mA
Accuracy
1)
(1500 – 2000 A) ± 5% of reading
Resolution ........................ ± 100 / ± 500 mA
Gain variation ................... ± 0.15% of reading/°C
Frequency range .................... DC to 20 kHz (-1 dB)
............................................. I
RMS
x f ≤ 400,000
Power supply .......................... 9 V Alkaline battery
............................................. PP3, MN 1604
............................................. or IEC6LR61
Load impedance (minimum) ..... > 100 k: and d 100 pF
General data
Conductor size ........................ 32 mm diameter
Output cable and connectors .... 2 m long coax terminated
............................................. with safety BNC connector
Operating temperature ............ 0 °C to +50 °C
Storage temperature with
Battery removed ..................... -20 °C to +85 °C
1)
Accuracy quoted is for conductor in centre of aperture
Fig 1
1. Jaws
2. Conventional current direction
3. Tactile Barrier
4. Battery cover
5. Battery cover screw
6. Jaw trigger
7. ON/OFF and Range switch
8. Auto zero button
9. LED
4
7
4
6
8
1
3
9
5
2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PICO TA167 and is the answer not in the manual?

PICO TA167 Specifications

General IconGeneral
BrandPICO
ModelTA167
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals