Page #1 background imageLoading...
Page #1 background image
To select indication of:
alarm time in hh.mm,
current day in DD.MM,
current year in YYYY,
current time in mm.ss,
current time in hh.mm,
press SELECT button
To select next
reference
modes press
SELECT
button
Current DE
threshold
value
(default value is
99 99)
Current DE
accumulated
time value
To return to
DE indication
mode press
SELECT
button
To turn on/off
alarm clock
press MODE
button
Sign of alarm clock
The DE threshold reference mode,
(Circular scale is filled)
The Time reference mode, (Alarm
time will be shown at first)
PM1208M Wrist Gamma Indicator
Quick Start Guide
Environmental operating conditions:
Temperature: 0 up to +45 °С ;
Humidity: up to 95% at 40°C ;
Water resistant
to a depth of 100 m;
Environmental protection IP68
www. polimaster.com
polimaster@polimaster.com
WARNING. Replace battery If bAtt
indicates. We recommend to make this in
a special watch repair office
During self-
test all LCD
segments will
flash for ~1 s
Linear analog
scale
To Start self-test
Press RESET button
Circular analog
scale
SELECT
button
MODE
button
Clock arrow
scroll button
LIGHT
button
The Dose Equivalent (DE) indication
mode, (mSv)
DE value
To select the
Time
indication
mode press
MODE button
To select DE
threshold SET
mode press and
hold SELECT
button
To select DE
references
modes press
SELECT
button
The Time indication mode,
(hh.mm)
To select the
DER indication
mode press
MODE button
To select Time
SET mode press
and hold SELECT
button
Time value
To select Time
references
modes press
SELECT button
Current DER
threshold
value
(default value
is 99 99)
To select next
reference
modes press
SELECT
button
To select next
reference
modes press
SELECT
button
Current number
of recording
(d - - - means
history is full )
To return to
DER indication
press SELECT
button
To record DER
value to history
press MODE
button
To start
registration
press MODE
button, DER
value will blink,
circular analog
scale will fill
The DER threshold reference
mode, (linear scale is filled)
(Linear
The DER recording to
history reference mode
(Linear
The DER registration reference
mode, ( 00.00 will displayed)
(Linear
After self-test the Dose Equivalent Rate (DER) indication
mode will be switched, (
Sv/h)
To select DER
threshold SET mode
press and hold
SELECT button
To select the DE indication
mode press MODE button
DER value
Voice alarm sign
To turn on/off
voice alarm press
and hold MODE
button 5 s
To select DER
references
modes press
SELECT button
The Communication with PC mode allows to make
additional settings (more detailed in p.3.2.6 of Manual)
To turn on PC
communication
mode press and
hold LIGHT
button
IR adapter should
be directed to this
point from 10-20 cm
PCon word will
be indicated

Other manuals for Polimaster PM1208M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polimaster PM1208M and is the answer not in the manual?

Polimaster PM1208M Specifications

General IconGeneral
BrandPolimaster
ModelPM1208M
CategoryWatch
LanguageEnglish