Frequency: 319.5MHz
Battery: 3V lithium CR123A
Magnet gap: 1 inch max
Operating Temperature: 32°-110°F (0°-45°C)
Operating Humidity: 5-85% RH non-condensing
Compatible with Qolsys control panels
Supervisory signal interval: 60 min (approximately)
Potentiometer: Shock sensitivity adjustment
Exterior Doors
Sliding
glass
doors
Windows
IQ SHOCK-S QUICK INSTALL GUIDE
CHOOSE
INSTALLATION
LOCATION
This is a quick guide for experienced installers only. Refer to http://dealers.qolsys.com (login required)
STEP
2
DIP!
SWITCH
CONFIGURATION
SPECIFICATIONS
STEP
1
DS#1 - Test Mode:
Enables sensitivity test
mode. !
Please note, when test mode is
enabled (ON) the IQ Shock will
NOT transmit signals to the IQ
Panel. This mode is only used
for initial installation of the
shock sensor.
ON:
OFF:
Disables sensitivity
test mode.
DS#2 - Pre-Warn:
ON:
Enables pre-warn
sounder and red LED.
OFF:
Disables pre-warn
sounder and red LED.
DS#3 - Reed Switch:
ON:
OFF:
Enables reed switch.
Disables reed switch.
ON
1
2
3
MAX
MIN
SENSOR
MAGNET
TAMPER
SWITCH
POTENTIOMETER
SHOCK
SENSOR
DIP
SWITCHES
LED
BUZZER
BATTERY
IMPORTANT NOTE:!
The IQ Shock is intended to be installed on doors with or without glass inserts and
on window frames but not on the actual glass surface.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the QOLSYS IQ SHOCK-S and is the answer not in the manual?

QOLSYS IQ SHOCK-S Specifications

General IconGeneral
BrandQOLSYS
ModelIQ SHOCK-S
CategoryAccessories
LanguageEnglish