15
INSTALLATION
EN
TCD1022 E / 1042 E - REV005A
INSTALLATION OF CONTROL PANEL
The control panel complies with EMC standards (electromagnetic compatibility) but requires correct installation to avoid com-
promising its performance and that of the surronding instruments.
For this reason the interface must be positioned at a distance of at least:
• 25 cm away from the compass.
• 50 cm away from any radio receivers.
• 1 m away from any radio transmitters (except for SSB).
• 2 m away from any radio transmitters SSB.
• 2 m away from the path of the radar beam.
After choosing where to position the controls, proceed as follows:
• Position the drilling template (provided) on the surface where the controls will be installed.
• Mark the centre of each hole.
• Drill the hole for the back of the instrument with a 60 mm bit.
• Remove the template and any burrs present in the hole.
• Insert the control panel into its seat.
• Fix the controls to the panel with four countersunk head screws (not provided).
• Position the frame on the controls.
TCD 1042 TCD 1022