FIGURE 27
VARIANT OF ALTERNATE
HORIZONTAL DIRECT-VENT
TERMINATION
DIRECT VENT (cont.)
GENERAL VENTING REQUIREMENTS AND
GUIDELINES
V
e
n
t
i
n
g
OPTION 4: ALTERNATE HORIZONTAL DIRECT-VENT TERMINATION
OPTION 5
: VARIANT OF ALTERNATE HORIZONTAL DIRECT-VENT TERMINATION
FIGURE 26
T
YPICAL HORIZONTAL VENTED 2 PIPE TERMINALS
ST-A1194-18-XO
FIGURES M, L, &
DETAILS B & C.
REDUCER / ADAPTER
2
EQUIV. VENT LENGTH
1
D
ETAIL A
COMBUSTION AIR TERMINATION
2” PVC
COUPLING
V
ANE
D
NOTE:
1) FOR EXHAUST / INTAKE PENETRATION
DIMENSIONAL RELATIONSHIP SEE
DETAIL C
N
OTE:
A
TRAP MUST BE IN-
S
TALLED IN THIS OPTION
T
O PREVENT WATER FROM
E
NTERING THE FURNACE
T
HROUGH THE COMBUS-
T
ION AIR PIPE. ORDER KITS
R
XGY-005 FOR 2” PIPE OR
R
XGY-D6 FOR 3” PIPE AND
I
NSTALL PER INSTRUC-
T
IONS IN KIT.
U.S. MIN. 12” (31cm)
ABOVE GRADE OR
ANTICIPATED AVG.
SNOW ACCUMULATION
CANADA: TERMINATION
MUST CONFORM TO CSA
B149.1-10, SECT. 8.14
5”
Max.
(13cm)
3”
Min.
(8cm)
60” Max. (152cm)
12”
(
31cm
)
INTAKE
A
B
E
XHAUST
INTAKE
1
2
(3
1
c
m)
60” Max. (152cm)
OR
CHOOSE
EITHER
ST-A1194-18-XO
FIGURES N & P &
DETAIL C
SEE DETAIL A
COUPLINGS: REQUIRED ON EXTERIOR,
OPTIONAL ON INTERIOR.
SEE DETAIL B FOR
DIMENSIONS BETWEEN
INTAKE & EXHAUST
10
NOTES:
1) SUPPORT HORIZONTAL PIPE EVERY FOUR FEET.
2) WHEN 3” PIPE IS USED REDUCE TO 2” BEFORE PENETRATING OUTSIDE WALL.
3) WHEN USING 3”
VENT AND NECKING DOWN AS REQUIRED, 18” (46cm) MAX. 2”
D
IA. PIPE MAY BE USED INSIDE WALL.
4
) INCREASE THE 12” (31cm) MIN. ABOVE GRADE (U.S.) TO KEEP TERMINAL
OPENINGS ABOVE ANTICIPATED LEVEL OF SNOW ACCUMULATION WHERE
APPLICABLE. CANADA: REFER TO B149.1, SECT. 8.14.
5) DETAIL“A” INSTALL WIND DEFLECTOR VANE IN 2” PVC COUPLING IN VERTICLE
POSITION USING PVC SOLVENT.
6) THE COMBUSTION AIR TERMINATION MUST BE IN THE SAME PRESSURE ZONE AS
THE EXHAUST TERMINATION.
7) NO SCREENS MAY BE USED TO COVER COMBUSTION AIR OR EXHAUST.
8) NO T’S CAN BE INSTALLED AT THE TERMINATION.
9) PIPING EXTERNAL TO THE STRUCTURE MUST BE INSULATED AS REQUIRED FOR
L
OCAL CLIMATE.
1
0) WALL PENETRATION AND VENT TERMINATION MUST BE WITH 2”
P
IPE.
OPTION B ONLY
NOTE:
1. A TRAP IN THE COMBUSTION AIR PIPE IS
NOT REQUIRED FOR THIS OPTION.
2. PIPING EXTERNAL TO THE STRUCTURE
MUST BE INSULATED FOR LOCAL CLIMATES.
3. WALL PENETRATION AND
VENT TERMINATIONS MUST
BE WITH 2” IPIE. A MAXI-
MUM OF 18” OF 2 PIPE IS
PERMITTED INSIDE (BE-
FORE THE PENETRATION)
WHEN USING 3” VENT.
U.S. MIN. 12” (31cm)
ABOVE GRADE OR
ANTICIPATED AVG.
SNOW ACCUMULATION
CANADA: TERMINATION
MUST CONFORM TO CSA
B149.1-10, SECT. 8.14
U.S. MIN. 12” (31cm)
ABOVE GRADE OR
ANTICIPATED AVG.
SNOW ACCUMULATION
CANADA: TERMINATION
MUST CONFORM TO CSA
B149.1-10, SECT. 8.14
61
DETAIL B
E
XHAUST / INTAKE RELATIONSHIP
4
” (10cm) MIN.
12”(31cm) MAX.
OPTIONAL
INTAKE
INTAKE
E
XHAUST
3 IN (8cm) MIN.
5 IN (13cm) MAX.
NOTE: This detail ap-
plies to the termination
and NOT the penetra-
tion through the wall.
60” Max. (152cm)
6”
(15.
5cm
) Mi
n.
Fro
m
W
al
l
18” Ma
x. (4
6cm)
3”
Min. (8cm)
INTAKE
1
2
” (3
1cm) F
ro
m Wa
ll
5
M
a
x
.
(1
3cm)
3
M
i
n.
(8cm)
OPTION A ONLY
NOTE: 1. A TRAP MUST BE INSTALLED IN THIS OPTION TO
PREVENT WATER FROM ENTERING THE FURNACE
THROUGH THE COMBUSTION AIR PIPE. ORDER
KITS RXGY-D05 FOR 2” PIPE OR RXGY-D06 FOR 3”
PIPE AND INSTALL PER INSTRUCTIONS IN KIT.
2. PIPING EXTERNAL TO THE STRUCTURE MUST BE
INSULATED FOR LOCAL CLIMATES
3. WALL PENETRATION AND VENT TERMINATIONS
MUST BE WITH 2” PIPE. WHEN USING 3” VENT
AND NECKING DOWN AS REQUIRED, A MAXIMUM
OF 18” OF 2” PIPE IS PERMITTED INSIDE (BE-
FORE THE PENETRATION) WHEN USING 3” VENT.
WIND VANE FROM
FURNACE PARTS BAG
EXHAUST
DETAIL APPLIES TO BOTH TERMINATIONS
SHOWN
NOTE: This de-
tail applies to the
termination and
NOT
the penetra-
tion through the
wall.
EXHAUST
U.S. MIN. 12” (31cm)
ABOVE GRADE OR
AVG. ANTICIPATED
SNOW ACCUMULATION
CANADA: TERMINATION
MUST CONFORM TO CSA
B149.1-10, SECT. 8.14