55
Maximum water temperature occurs while the
water heater burner is on. To determine the water
temperature:
Turn on the hot water faucet and place a
thermometer in the water stream.
NOTICE:
Water temperature at the faucet may vary
depending on the season and the length of pipe
from the water heater.
The control temperature range is between 100°F (38°C)
and 120°F (49°C)� To adjust the temperature to a desired
setting, press the UP or DOWN adjustment button on the
face of the control� The new temperature set point will
show on the LED display
NOTICE:
The temperature set point on the standard remote
control cannot be increased above 112°F (44°C)
when a hot water faucet is in the open position.
To achieve temperatures above 120°F (49°C),
contact a qualified service technician. Only
factory-authorized remote control(s) should be
used.
The water heater may not operate with a small water flow
(<0�4 gpm)� Increase the water flow and recheck� If it still
does not operate with the hot water faucet completely open,
increase the temperature setting on the remote control�
Water Heater Facts
!
DANGER:
Water temperatures above 125°F (52°C) will result
in death and/or severe burns from scalding.
The hottest-temperature water will be at the faucet closest
to the water heater
Always remember to test the water temperature with your
hand before use�
Always supervise young children or others who are
incapacitated�
The water heater is equipped with a device that will shut
off the gas supply to the burner if the water heater exceeds
normal operating temperatures�
Any water heater that has been subjected to fire, flood,
physical damage, or been under water should be turned off
at the manual gas shut-off valve and not used until it has
been checked by qualified service personnel�
Setting the Water Temperature (cont.)
Use Instructions
!
PRIORITY
In-Use Indicator
(Lit during operation)
In-Use Indicator
(Lit during operation)
Priority
Indicator
Priority
Indicator
Power On/Off
Indicator
Temperature
Adjustment
Buttons
Temperature
Adjustment
Buttons
WiFi
Button
Priority
Indicator
Power On/Off
Indicator
In-Use Indicator
Lit during operation
Alarm/ Error
Indicator
WiFi Signal
Indicator
Power On/
Off Button
LED Temperature
and Error Code
Display
LED Temperature
and Error Code
Display
Power On/Off
Button
(WiFi model only)(Outdoor model only)
LED DISPLAY LED WiFi DISPLAY
Power On/Off
Button
Temperature
Adjustment
Buttons
USING YOUR WATER HEATER