Sununo Plus Series
-16-
AC Short Circuit Current
Protection
Integrated
Thermal Protection Integrated
Anti-island protection
monitoring
AFD
Interface
AC Connection Plug-in connector
DC Connection MC4/H4
LCD/LED Display LCD (16x2 Characters, Backlight) & LED (3 Lights)
Display Language English
Datalogger & Communication RS232 (Standard)/WiFi (Optional)
General Data
Topology Transformerless
Consumption at Night [W] <0.2
Consumption at Standby [W] 6
Operating Temperature Range
-25
°
Cto+60
°
C(45
°
Cto60
°
C with derating)
Cooling Method Natural Covection
Ambient Humidity 0% to 98% Non-condensing
Altitude Up to 2000m (without derating)
Noise [dBA] <25
Ingress Protection IP65 (Indoor & Outdoor Installation)
Mounting Rear Panel
Dimensions (H*W*D) [mm] 454*355*150 454*355*162
Net Weight [kg] 14.8 15.8
Standard Warranty [Year]
5
(
Standard
)
/10/15/20/25
(
Optional
)
Certificates
IEC62109-1/2, IEC61000-6-2/3, IEC61683, IEC60068-2,
IEC62116, IEC61727, PEA/MEA, NRS 097-2-1,
UTE-C-15-712-1, VDE0126-1-1/A1, VDE-AR-N 4105,
AS4777.2, AS4777.3, C-TICK, CQC NB/T 32004, G83-2,
G59-3, NBR 16149, NBR 16150, TF 3.2.1, C10/11
Remark:
1. Meet the grid standard that AC current per phase not exceeding 16A.
2. Meet the VDE - ARN - N 4105 that biggest apparent power of single-phase is
4600 VA.