Method 2:
Under monitoring mode interface, press key, switch to next monitoring parameter item d-xx, press key to
move flicker bit to ones digit of the monitoring code, then adjust key or key until the monitoring code displays
d-05, then operate according to step 2 and step 3 of method 1.
Example 3: check fault monitoring parameter in fault status
Under fault status press key and check D group monitoring parameter ranging from D-00 to D-57.
If the fault wasn’t eliminated during checking the fault parameter, the interface will automatically switch to fault alarm
display 5s later after stopping operation.
The fault code displays ranging from D-48 to D-57 (the current status and latest 3 times).
3.8 Function Code Setting
The function parameter system of this inverter includes function code F0FF, fault code E group and monitoring code D
group. Each function group is consisted of several function code, which is marked as (function group code + function
code). For example, “F5.08” means eighth function code in the fifth function group.
Function code setting example:
Example 1: change frequency setting of forward jogging form 5Hz to 10Hz (F1.20 modified from 5.00Hz to 10.00Hz)
Press key to enter programming status, LED displays function code F0.00, flicker bit stays in the ones
digit.
Escape
*****

Questions and Answers: