EasyManuals Logo

Schlage M490 User Manual

Schlage M490
9 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
*44487296*
44487296
M490 Armature
plate assembly
M420/M450
Armature plate assembly
Single Electromagnetic Locks: M420, M450, M490
M400 Series
Installation Instructions
Features
Automatic Voltage Selection (AVS)
Magnet immediately detects 12VDC or 24VDC when power is
connected.
Anti-Tamper Switch (ATS)
An indication is provided should the magnet cover become
unsecured from lock.
Magnetic Bond Sensor (MBS)
Detects proper bond between magnet and armature. It can be
monitored remotely and locally with an LED.
LED
Provides local indication of MBS status.
Door Position Switch (DPS)
Indicates whether door is open or closed. This feature is used in
conjunction with the MBS.
Relock Time Delay (RTD)
Relock time can be changed. Range is 1 - 30 seconds.
Models
M420 (Trafc Control)
UL1034 and 10C/500lb and 3hr rating
M450 (High Security)
UL1034 and 10C/1000lb and 3hr rating
M490 (Max Security)
UL1034 and 10C/1500lb and 3hr rating
Trims
Basic
Auto Voltage Selection (AVS) for 12 or 24VDC
Plus
Basic features + Door Position Switch (DPS), Magnetic Bond
UL Requirements
Units shall not impair operation of panic hardware mounted on door.
Units shall not impair intended operation of an emergency exit.
Units/Models are intended to be connected to UL Listed Equipment, not
intended for Burglar or Fire Alarm Initiating or Indicating Devices.
Ambient Conditions - “For Indoor Use Only”.
This device complies with part 15 of FCC rules.
Operation is subject to following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including any
interference that may cause undesired operation. Changes or
modications not expressly approved by party responsible for compliance
could void user’s authority to operate equipment.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schlage M490 and is the answer not in the manual?

Schlage M490 Specifications

General IconGeneral
Holding Force1500 lbs
Voltage12/24V DC
Operating Temperature-40°F to 140°F (-40°C to 60°C)
Static Strength1500 lbs
HandingNon-handed
ANSI GradeGrade 1
Lock TypeElectromagnetic
Current Draw12VDC/500mA; 24VDC/250mA
Fail Safe/Fail SecureFail Safe
Door Thickness1.75" (44.45mm)
StrikeArmature Plate
ConstructionAluminum

Related product manuals