ND-Series Electrified Lock
For standard installation, see full instruction sheet.
Select the appropriate mode for the installation using the mode select switch located on the chassis. Note: When mode is
switched (from EL to EU or EU to EL) the lock requires a complete lock/unlock power cycle to synchronize to the proper mode.
EL, electrically locked (fail safe):
Outside knob/lever or both outside and inside knobs/levers (depending on function) will lock when power is applied. In the event of power
failure, the opening will be unlocked.
EU, electrically unlocked (fail secure):
Outside knob/lever or both outside and inside knobs/levers (depending on function) will unlock when power is applied. In the event of
power failure, the opening will be locked.