R-210D
13
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
O PROCEDURES TO BE TAKEN WHEN THE FOIL PATTERN ON THE PRINTED WIRING
BOARD(PWB) IS OPEN
To protect the electronic circuits, this model is provided with a fine foil pattern added to the input circuit
on the PWB, this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide
given below for repair.
Problem: POWER ON, indicator does not light up.
CARRY OUT 3D CHECKS.
STEPS OCCURRENCE CAUSE OR CORRECTION
1 The rated AC voltage is not present at Check supply voltage and oven power cord.
Power terminal of CPU connector (CN-A).
2 The rated AC voltage is present at primary Low voltage transformer or secondary circuit defective.
side of low voltage transformer. Check and repair.
3 Only pattern at "a" is broken. *Insert jumper wire J1 and solder.
(CARRY OUT 3D CHECKS BEFORE REPAIR)
4 Pattern at "a" and "b" are broken. *Insert the coil RCILF2003YAZZ between "c" and "d".
(CARRY OUT 3D CHECKS BEFORE REPAIR)
NOTE: *At the time of these repairs, make a
visual inspection of the varistor for
burning damage and examine the
transformer with tester for the pres-
ence of layer short circuit (check pri-
mary coil resistance).
If any abnormal condition is detected,
replace the defective parts.
CARRY OUT 4R CHECKS.
(J1)
CN - A
ab
c
d
15
1
P
T1
VRS1
RY1