DC. voltage indicated ................... Defective relay.
DC. voltage not indicated ............. Check diode which is connected to the relay coil. If diode is good,
control unit is defective.
RELAY SYMBOL OPERATIONAL VOLTAGE CONNECTED COMPONENTS
RY1 Approx. -12.0V D.C. Oven lamp / Turntable motor / Cooling fan motor
RY2 Approx. -11.0V D.C. Power transformer
8. Disconnect the power supply cord, and then remove outer case.
9. Open the door and block it open.
10. Discharge high voltage capacitor.
11. Reconnect all leads removed from components during testing.
12. Re-install the outer case (cabinet).
13. Reconnect the power supply cord after the outer case is installed.
14. Run the oven and check all functions.
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
d
ab
c
WARNING : The oven should be fully assembled before following procedure.
(1) Place one cup of water in the center of the turntable tray in the oven cavity.
(2) Close the door, touch the “ DEFROST ” pad once. And then touch the number pad 2.
(3) Touch the number pad 5 and then touch the start pad.
(4) The oven is in Defrost cooking condition.
(5) The oven will operate as follows.
MENU 1ST STAGE 2ND STAGE 3RD STAGE
Steaks/Chops LEVEL TIME LEVEL TIME LEVEL TIME
0.5lb 70% 17sec. 60% 27sec. 30% 40sec.
(6) If improper operation is indicated, the control unit is probably defective and should be checked.
L DEFROST TEST
To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on the PWB,
this foil pattern acts as a fuse.
1. Foil pattern check and repairs.
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Follow the troubleshooting guide given below for repair.
STEPS OCCURRENCE CAUSE OR CORRECTION
1 Only pattern at “a” is broken. *Insert jumper wire J1 and solder.
2 Pattern at “a” and “b” are broken. *Insert the coil RCILF2003YAZZ between “c” and “d”.
5) Make a visual inspection of the varistor. Check for burned
damage and examine the transformer with a tester for the
presence of layer short-circuit (check the primary coil
resistance which is approximately 563 ± 10%). If any
abnormal condition is detected, replace the control unit
assembly.
6) Reconnect all leads removed from components during
testing.
7) Re-install the outer case (cabinet).
8) Reconnect the power supply cord after the outer case is
installed.
9) Run the oven and check all functions.
2. Follow the troubleshooting guide given below, if indicator
does not light up after above check and repairs are finished.
1) Disconnect the power supply cord, and then remove
outer case.
M FOIL PATTERN ON THE PRINTED WIRING BOARD TEST

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp R-308JS and is the answer not in the manual?

Sharp R-308JS Specifications

General IconGeneral
BrandSharp
ModelR-308JS
CategoryMicrowave Oven
LanguageEnglish

Related product manuals