TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
D HIGH VOLTAGE CAPACITOR TEST
CARRY OUT
3D CHECKS.
A. Isolate the high voltage capacitor from the circuit.
B. Continuity check must be carried out with measuring instrument which is set to the highest resistance
range.
C. A normal capacitor shows continuity for a short time (kick) and then a resistance of about 10M after
it has been charged.
D. A short-circuited capacitor shows continuity all the time.
E. An open capacitor constantly shows a resistance about 10 M because of its internal 10M resistance.
F. When the internal wire is opened in the high voltage capacitor shows an infinite resistance.
G. The resistance across all the terminals and the chassis must be infinite when the capacitor is normal.
If incorrect reading are obtained, the high voltage capacitor must be replaced.
CARRY OUT
4R CHECKS.
E SWITCH TEST
CARRY OUT
3D CHECKS.
Isolate the switch to be tested and using an ohmmeter check between the terminals as described in the
following table.
Table: Terminal Connection of Switch
Plunger Operation COM to NO COM to NC COM; Common terminal
Released Open circuit Short circuit NO; Normally open terminal
Depressed Short circuit Open circuit NC; Normally close terminal
If incorrect readings are obtained, make the necessary switch adjustment or replace the switch.
CARRY OUT
4R CHECKS.
F NOISE FILTER TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the terminals of the noise filter.
Using an ohmmeter, check between the terminals as de-
scribed in the following table.
MEASURING POINT INDICATION OF OHMMETER
Between N and L Open circuit
Between terminal N and WHITE Short circuit
Between terminal L and RED Short circuit
If incorrect readings are obtained, replace the noise filter unit.
CARRY OUT 4R CHECKS.
G MONITOR RESISTOR TEST
CARRY OUT
3D CHECKS.
Disconnect the leads from the monitor resist. Using an ohmmeter and set on a low range. Check
between the terminals of the monitor resistor.
The resistance of monitor resistor is
approx. 0.8 ohms.
If incorrect readings are obtained, replace the monitor resistor.
CARRY OUT
4R CHECKS.
FUSE
M10A
NOISE SUPPRESSION COIL
N L
0.0022µ/AC 250V
0.0022
µ/AC 250V
LINE CROSS CAPACITOR
0.068
µ/AC250V
WHT RED
CARRY OUT
3D CHECKS.
Disconnect the leads from the terminals of the temperature fuse or thermal cut-out. Then using an
ohmmeter, make a continuity test across the two terminals as described in the table below.
H TEMPERATURE FUSE OR THERMAL CUT-OUT TEST

Questions and Answers: