No.:2012-12-001
I DT SNC M3S
808D set point cable X51~
~~
~X53 connecting with V60 driver instructions
1. 808D PPU interface X51~X53 is defined as axis pulse interface, the standard configuration is
SINAMCIS V60 drive.
( Taking a milling machine for an example)
2. The detail interface signal for Standard configuration SINAMCIS V60 drive as below:
808D PPU
X51~X53 port
symbol(colour)
The description of signal V60 port /pin
Remark
1
PULSE+ (green)
Positive pulse(NC output signal)
X5 / pin1 5V signal
9 PULSE- (yellow)
Negative pulse(NC output signal)
X5 / pin2 5V signal
2 DIR+ (gray)
DIRECTION +(NC output signal)
X5 / pin3 5V signal
10 DIR- (pink)
DIRECTION -(NC output signal)
X5 / pin4 5V signal
3 ENA+ (brown)
Pulse enable+(NC output signal)
X5 / pin5 5V signal
11 ENA- (white)
Pulse enable-(NC output signal)
X5 / pin6 5V signal
65
servo enable(NC output signal)
X6 / pin1
+24V=drive
enable
0V=drive disable
6
RST
(white/green)
Alarm Reset(NC output signal)
X6 / pin2 + 24V high active
7 M24 (red)
Servo enable and ALARM RESET
Ground
X6 / pin3
5
ALM1
(red/blue)
Power from the pin 1 of X200,
+24V output
X6 / pin4
15 ALM2 (blue)
Alarm, from drive side(NC input
signal)
X6 / pin5
When alarm is
triggered,ALM1,
ALM2 close
8 RDY1 (black)
Power from the pin 1 of X200,
+24V output
X6 / pin6
14 RDY2 (purple)
Drive ready signal ( NC input
signal)
X6 / pin7
drive is ready, the
line close.