Product type designation | FM 450-1 |
---|---|
Category | Measuring Instruments |
Manufacturer | Siemens |
Series | SIMATIC S7-400 |
Number of channels | 1 |
Counting frequency, max. | 500 kHz |
Supply voltage | 24 V DC |
Resolution | 32 bit |
Operating temperature | 0 to 60 °C |
Storage temperature | -40 °C to 70 °C |
Relative humidity | 5% to 95%, non-condensing |
Weight | Approx. 0.6 kg |
Provides an overview of the manual's content and intended audience.
Lists the essential prerequisites for understanding the manual's technical content.
Offers guidance on where to find further assistance and documentation.
Details the technical characteristics and capabilities of the FM 450-1 counter module.
Illustrates the physical components and layout of the FM 450-1 module.
Explains the software packages and configuration interfaces required for the FM 450-1.
Introduces fundamental concepts of counting, count ranges, and operating modes for the FM 450-1.
Describes how to control counting processes using software and hardware gates.
Outlines crucial steps and considerations before installing the FM 450-1 module.
Provides a step-by-step guide for physically installing the FM 450-1 module into a system.
Lists the specific functions of each terminal on the FM 450-1 front connector.
Describes the functionality and connection of the digital inputs for the FM 450-1.
Guides users on installing and accessing the software tools for configuring the FM 450-1.
Explains the core function block (FC CNT_CTRL) for controlling the FM 450-1 counters.
Describes the function block for reading diagnostic data from the FM 450-1.
Provides a checklist for verifying mechanical installation tasks for the FM 450-1.
Outlines steps for assigning parameters to the FM 450-1 counters, covering encoder selection and modes.
Presents the available operating modes, settings, and commands for the FM 450-1.
Describes how to control counting processes using hardware and software gates.
Explains how to set the counter to a specific load value using various inputs or program commands.
Details how to configure events to trigger hardware interrupts during module operation.
Lists the types of encoders compatible with the FM 450-1 and their signal characteristics.
Explains the signal types and evaluation for 5-V incremental encoders.
Describes the signal types and evaluation for 24-V incremental encoders and pulse generators.
Details the data block structure and assignments used by the FC CNT_CTRL function.
Explains how internal and external faults are displayed via module LEDs.
Describes how to enable and respond to diagnostic interrupts triggered by module faults.
Covers types of data errors, their causes, and how to acknowledge them.
Explains operator errors, their causes, and how to acknowledge them.
Refers to standards, EMC, shipping, storage, and environmental conditions.
Provides detailed specifications for dimensions, weight, voltages, currents, and power loss.
Lists available accessories and spare parts for ordering.
Lists other manuals referenced within this document.
Defines encoders and their role in precise signal recording for industrial applications.
Explains the purpose and operation of function modules in automation systems.