NOTICE
Overheating caused by solar radiation
Overheating of the geared motor due to exposure to direct sunlight.
Provide suitable protective equipment such as covers or roofs. Prevent heat accumulation.
NOTICE
Malfunction resulting from foreign objects
The operator must ensure that no foreign objects impair the function of the gearbox.
NOTICE
Damaged components impair the correct function of the gearbox
If any components are damaged, the correct function of the gearbox will no longer be ensured.
Do not install any damaged gearbox components.
NOTICE
Violation of the maximum permissible oil sump temperature
The oil sump temperature will be exceeded if the temperature monitoring equipment is
incorrectly set.
An alarm must be output when the maximum permissible oil sump temperature is reached. The
geared motor must be switched o󹪜 when the maximum permissible temperature is exceeded.
The machine will come to a standstill if the geared motor is shut down.
Note
Use headless screws with property class8.8 or higher to fasten the motor.
Exercise particular care during mounting and installation. The manufacturer cannot be held
liable for damage caused by incorrect mounting and installation.
Make sure that there is su󹪟cient space around the gearbox or geared motor for mounting,
maintenance and repair.
On geared motors with a fan, leave su󹪟cient free space for air to enter. Observe the
installation conditions for the geared motor.
Provide adequate lifting gear at the start of mounting and installation work.
Observe the mounting position speci󹪝ed on the rating plate. This ensures that it will be
provided with the correct quantity of lubricant.
Use all the fastening means that have been assigned to the particular mounting position and
mounting type.
Cap bolts cannot be used in some cases due to a lack of space. In such cases, please contact
Technical Support, specifying the type of gearbox.
Additional information on the SIMOGEAR geared motor
12.1General information geared motor with SINAMICS G115D Motor Mounted / Wall Mounted
SINAMICS G115D Wall Mounted distributed drive
434 Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G115D and is the answer not in the manual?

Siemens SINAMICS G115D Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS G115D
CategoryDC Drives
LanguageEnglish

Related product manuals