EasyManuals Logo

Siemens SINAMICS V90 User Manual

Siemens SINAMICS V90
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #79 background imageLoading...
Page #79 background image
General information
2.7 Technical data
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
77
2.7.2.3
Power derating
For deviating conditions (surrounding temperature > 40 °C or installation altitude > 1000 m
above sea level) the permissible torque/power must be determined from the following table.
Surrounding temperatures and installation altitudes are rounded off to 5 °C and 500 m
respectively.
Power derating as a function of the installation altitude and ambient temperature
Installation altitude above
sea level (m)
Surrounding temperature in °C
< 30
30 to 40
45
50
55
1000 1.07 1.00 0.96 0.92 0.87
1500
1.04
0.97
0.93
0.89
0.84
2000
1.00
0.94
0.90
0.86
0.82
2500
0.96
0.90
0.86
0.83
0.78
3000
0.92
0.86
0.82
0.79
0.75
3500
0.88
0.82
0.79
0.75
0.71
4000 0.82 0.77 0.74 0.71 0.67

Table of Contents

Other manuals for Siemens SINAMICS V90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS V90 and is the answer not in the manual?

Siemens SINAMICS V90 Specifications

General IconGeneral
Power Range0.05 kW to 7.0 kW
Protection ClassIP20
CommunicationUSS/Modbus RTU
FeedbackIncremental encoder
Input Voltage1AC 200 V to 240 V, 3AC 380 V to 480 V
Control ModesPosition, Speed, Torque
Operating Temperature0 °C to +40°C
Storage Temperature-40°C to +70°C
Relative Humidity5% to 95% (non-condensing)
AltitudeUp to 1000 m above sea level