Features
4100ES Series MINIPLEX transponders allow
remotely located initiating and notification
functions:
Transponder operation is available as standard or with
local mode operation
Communications with the host fire alarm control panel
use the Remote Unit Interface (RUI/RUI+) format
Initiating functions include:
Addressable device support including TrueAlarm
analog sensor compatibility
Conventional initiating device circuit (IDC) support
Notification functions include:
Addressable strobe and horn notification using
enhanced power delivery IDNAC SLCs
Emergency voice/alarm communications
Conventional DC notification appliance circuits (NACs)
Local mode operation provides:
Default local initiating and notification operation in the
event of a communications loss with the host control panel
Enabling of an optional Local Mode Controller with a
local alarm sounder, LED status indicators, and
keyswitch enabled control switches
Support for IDNet addressable devices, addressable and
conventional notification appliances, and default output
tones from local amplifiers
Optional modules include:
Digital or Analog audio riser modules for connection to
system audio signals
Digital or analog input audio amplifiers with integral
on-board NACs
Power supplies with or without battery chargers
City Connect modules and RS-232 ports for printers or
maintenance terminals
Alarm relays, auxiliary relays, additional IDC modules,
and NAC expansion modules
Cabinets are equipped with solid doors (beige or
red) and in one, two, or three bay sizes
Listed to:
UL Std. 864, Fire Detection and Control (UOJZ), and
Smoke Control Service (UUKL)
UL Std. 2017, Process Management Equipment (QVAX)
UL Std. 1076, Proprietary Alarm Units-Burglar (APOU)
UL Std. 1730, Smoke Detector Monitor (UULH)
ULC Std. S527-99
* See pages 4 and 5 for product that is listed as UL or ULC. This product has been approved by
the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health
and Safety Code. See CSFM Listing 7165-0026:0251 for allowable values and/or conditions
concerning material presented in this document. Additional listings may be applicable; contact
your local Simplex product supplier for the latest status. Listings and approvals under Simplex
Time Recorder Co. are the property of Tyco Fire Protection Products.
4100ES Fire Alarm Control Panel
with Voice Control
ALARMFIRE
PULL DOW N
IDNet addressable
devices
Audio NAC
Fire Alarm Local Mode Controller
ENABLE
CONTROL
Alarm
Alarm
Silenc ed
Local
Mode
Active
Power
On
Alarm
Silence
Reset
Local
Mode
Control
Local mode
controller
Addressable strobes
on IDNAC SLC
MINIPLEX
transponder
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
On
Off
Auto
Press ACK located under flashing indicator.
Repeat operation until all events are acknowledged.
Local tone will s ilence.
A B C
AC Power
D E F G H I
J K LM N OP Q R
'SP' ( ) , 0 :
S T U V W X Y Z /
ALARMS
Fire Alarm Priority 2 Alarm
SYSTEM WARNINGS
Supervisory Trouble
Alarm Silenced
Emergency Operating Instructions
Alarm or Warning Condition
How to Acknowledge / View Events
How to Silence Building Signals
System indicator flashing. Tone On. Press Alarm Silence.
How to Reset System
Press System Reset.
Press Ack to silence tone device.
ZONE
1
SIG
2
AUX
3
FB
4
IO
5
IDNet
6
P
7
A
8
L
9
NET ADDR
0
DEL
Enter C/Exit
Fire Alarm
Ack
Priority 2
Ack
Supv
Ack
Trouble
Ack
Alarm
Silence
System
Reset
Event
Time
Enable
On
Arm
Disable
Off
Disarm
Auto
Lamp
Test
More
Info
Menu
Previous
Next
C
A
U
T
I
O
N
C
A
U
T
I
O
N
DISCONNECT
A.C. POWE R
AND
BATTERY
BEFORE
SERVICING
DISCONNECT
A.C. POWER
AND
BATTERY
BEFORE
SERVICING
Typical 4100ES MINIPLEX System One-Line Drawing
Introduction
4100ES MINIPLEX transponders connect to a host
4100ES Fire Alarm Control Panel using Simplex
®
remote
unit interface (RUI) communications. At the transponder,
RUI communications are received by the transponder
interface module and translated into the same internal
communications format that is used in the host control
panel.
Remotely located modules. With RUI
communications, the transponder can remotely provide
the same initiating and notification functions that occur at
the host control panel without requiring multiple long
distance wiring runs. Connections to the host panel are
low current communications and audio wiring with
distances up to 2500 ft (762 m).
Additional Reference. Refer to document S4100-0100
and the other documents listed on page 3 for additional
information concerning the extensive initiating and
notification features of the 4100ES fire alarm control
panels.
4100ES Fire Control Panels
UL, ULC, CSFM Listed; Addressable Fire Detection and Control
FM Approved * MINIPLEX Transponders
S4100-0103 5/2013

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simplex MINIPLEX 4100ES Series and is the answer not in the manual?

Simplex MINIPLEX 4100ES Series Specifications

General IconGeneral
BrandSimplex
ModelMINIPLEX 4100ES Series
CategoryMarine Radio
LanguageEnglish