Dolby Laboratories.
Amplifier section
Power Output
1)
Models of area code SP, MX, E51
(6 ohms 1 kHz, THD 0.7%)
FRONT
2)
: 80 W/ch
CENTER
2)
: 80 W
SURR
2)
: 80 W/ch
SURR BACK
2)
: 80 W
(6 ohms 1 kHz, THD 10%)
FRONT
2)
: 130 W/ch
CENTER
2)
: 130 W
SURR
2)
: 130 W/ch
SURR BACK
2)
: 130 W
Models of area code AUS
(6 ohms 120 Hz – 20 kHz, THD 0.09%)
FRONT
2)
: 70 W/ch
CENTER
2)
: 70 W
SURR
2)
: 70 W/ch
SURR BACK
2)
: 70 W
(6 ohms 1 kHz, THD 0.7%)
FRONT
2)
: 80 W/ch
CENTER
2)
: 80 W
SURR
2)
: 80 W/ch
SURR BACK
2)
: 80 W
(6 ohms 1 kHz, THD 10%)
FRONT
2)
: 130 W/ch
CENTER
2)
: 130 W
SURR
2)
: 130 W/ch
SURR BACK
2)
: 130 W
1) Measured under the following conditions:
2) Depending on the sound field settings and the
source, there may be no sound output.
Inputs (Analog)
Area code Power requirements
SP, SP6 230 V AC, 50 Hz
AUS, E51 240 V AC, 50 Hz
MX 127 V AC, 60 Hz
MULTI CH IN,
SA-CD/CD, MD/TAPE,
DVD, VIDEO 1, 2, 3
Sensitivity: 800 mV
Impedance: 50 k ohms
Inputs (Digital)
Outputs (Analog)
Reproduction frequency range:
28 – 20,000 Hz
Tone
DVD (Coaxial) Sensitivity: –
Impedance: 75 ohms
VIDEO 2, SA-CD/CD
(Optical)
Sensitivity: –
Impedance: –
MD/TAPE (OUT),
VIDEO 1 (AUDIO OUT)
Voltage: 800 mV
Impedance: 10 k ohms
SUB WOOFER Voltage: 2 V
Impedance: 1 k ohm
Gain levels ±6 dB, 1 dB step
FM tuner section
Tuning range 87.5 - 108.0 MHz
Antenna FM wire antenna
Antenna terminals 75 ohms, unbalanced
Intermediate frequency 10.7 MHz
AM tuner section
Tuning range
Models of area code SP, SP6, AUS
With 9-kHz tuning scale: 531 – 1,602 kHz
Models of area code E51
With 10-kHz tuning scale: 530 – 1,610 kHz
3)
With 9-kHz tuning scale: 531 – 1,602 kHz
3)
Models of area code MX
With 10-kHz tuning scale: 530 – 1,610 kHz
Antenna Loop antenna
Intermediate frequency 450 kHz
3) You can change the AM tuning scale to 9 kHz or 10
kHz. After tuning in any AM station, turn off the
receiver. While holding down PRESET TUNING +
or TUNING +, press ?/1. All preset stations will be
erased when you change the tuning scale. To reset
the scale to 10 kHz (or 9 kHz), repeat the procedure.