EasyManuals Logo

Sungrow SG125CX-P2 User Manual

Sungrow SG125CX-P2
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #107 background imageLoading...
Page #107 background image
7 iSolarCloud App User Manual
AFCI Parameters
The AFCI function may not be applicable in some areas. Please consult SUNGROW
for details.
Tap Settings > Operation Parameters > AFCI Parameters to enter the corresponding screen,
on which you can set AFCI Parameters.
figure 7-15 AFCI Setting
NS Protection (Passive Valid)
Tap Settings > Operation Parameters > Regular Parameters to enter the corresponding
screen, on which you can set the NS Protection(Passive Valid).
figure 7-16 NS Protection(Passive Valid)
7.8.3 Power Regulation Parameters
Active Power Regulation
Tap Settings > Power Regulation Parameters > Active Power Regulation to enter the
screen, as shown in the following figure.
98

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG125CX-P2 and is the answer not in the manual?

Sungrow SG125CX-P2 Specifications

General IconGeneral
Max. DC Voltage1100 V
Rated AC Power125 kW
Max. DC Power150 kW
Start-up Voltage200 V
MPPT Voltage Range200 V - 1000 V
Max. Short-circuit Current per MPPT40 A
Max. AC Power137.5 kW
Max. AC Current198 A
Rated AC Voltage400 V
Rated Grid Frequency50/60 Hz
Total Harmonic Distortion<3%
Power Factor Adjustment Range0.8 leading to 0.8 lagging
DC Connection TypeMC4
Protection ClassIP66
Maximum DC Input Power150 kW
DC Inputs per MPPT2
Cooling MethodSmart forced air cooling
Operating Temperature Range-25°C to +60°C
Humidity Range0 - 100%
CommunicationRS485, Ethernet