Commands Listed in Alphabetical Order
Arguments
OFF removes the
cursors from the display but does not change the cursor type.
SCREEN specifies both horizontal and vertical bar cursors, which measure the
selected wave
form in horizontal and vertical units. Use the se cursors to measure
anywhere in the waveform display area.
WAVEform sp
ecifies paired cursors in YT display format for measuring waveform
amplitude and time. In XY and XYZ format, these cursors indicate the amplitude
positions of an XY pair (Ch1 vs Ch2 voltage, where Ch1 is the X axis and Ch2 is
the Y axis) relative to the trigger.
VBArs specifies the vertical bar cursor to measure the selected waveform in
vertical units.
HBArs specifies the h orizontal bar cursor to measure the selected waveform in
horizontal units.
Examples
CURSOR:FUNCTION WAVEFORM selects the paired cursors for measuring waveform
amplitude and time.
CURSOR:FUNCTION? might return :CURSor:FUNCtion SCREEN indicating that
the screen cursors are currently selected.
CURSor:HBArs? (Query Only)
Returns the current settings for the horizontal bar cursors.
Group
Cursor
Syntax
CURSor:HBArs?
Examples
CURSOR:HBARS? might return the horizontal
bar setting as
:CURSOR:HBARS:POSITION1
320.0000E-03;POSITION2-320.0000E-03;UNITS BASE
CURSor:HBArs:DELTa? (Query Only)
Returns the vertical difference between the two horizontal bar cursors.
Group
Cursor
Syntax
CURSor:HBArs:DELTa?
2-11 2 MSO2000B, DPO2000B, MSO2000 and DPO2000 Series O scilloscopes Programmer Manual