18-GE02D2=4
Convertible Air Handlers
1=1/2- 5 Ton for R-410A
4TEP3F18A1000A 4TEP3F36A1000A
4TEP3F24A1000A 4TEP3F42A1000A
4TEP3F30A1000A 4TEP3F48A1000A
4TEP3F48B1000B
4TEP3F63A1000A
4TEP3F63B1000B
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT -- This Document is customer property and is to remain with this unit. Please return to service
information pack upon completion of work.
A. GENERAL iNFORMATiON
THIS iNFORMATiON iS FOR USE BY iNDiViDUALS
HAVING ADEQUATE BACKGROUNDS OF ELECTRICAL
AND MECHANICAL EXPERIENCE. ANY ATTEMPT TO
REPAIR A CENTRAL AiR CONDiTiONiNG PRODUCT
MAY RESULT iN PERSONAL iNJURY AND/OR PROP=
ERTY DAMAGE. THE MANUFACTURER OR SELLER
CANNOT BE RESPONSIBLE FOR THE INTERPRETA-
TION OF THiS iNFORMATiON, NOR CAN iT ASSUME
ANY LiABiLiTY iN CONNECTION WiTH iTS USE.
Contents
General information ...........
installationLimitations& ...........
Unit Installation
Upflow
Downflow
HorizontalLeft
HorizontalRight
To prevent shortening its service life, the air handler
should not be used during the finishing phases of
construction. The low return air temperaturescan lead
to the formation of condensate. Condensat_ ;i_;;;the
presence of chloridesand fluorides from pai;!i _ish,
stains, adhesives, cleaning ......
createsacorrosive .........
deterioration of the cabinet _;_ int_ _al _p ;_ents.
These instructions cover 811v_ i ;_ns in sys-
tems or provide for Should
further _formation e _ _ed o} particular problems
ar_ _ :are_ _ sufficiently by this manual,
co ;t No lo ::_ distributor or the manufacturer as
handler nameplate.
Thes_:_r Ha_lers are shipped from the factory in the
upflow horizontal right configuration and are fully
convertible to downflow or horizontal left. Refer to
Section B beginning on page 3 for additional information.
iNSPECTiON
Check carefully for any shipping damage. This must be
reported to and claims made against the transportation
company immediately. Check to be sure all major
components are in the unit. Any missing parts should
be reported to your supplier at once, and replaced with
authorized parts only.
Drain Piping
Eh -- Power Wiring
Control Wiring
Checkout Procedure
Hook-up Diagrams
Outline Drawings
Cardboard packing material must be removed from
inside the blower assembly before starting the unit.
Failure to do so may cause indoor blower motor failure.
INSTALLATION LIMITATIONS & RECOMMENDATIONS
The general location of the air handler is normally
selected by the architect, contractor and/or home owner
for the most effective application and satisfaction.
These air handlers are suitable for installation in a closet,
alcove or utility room with free, non-ducted, air return,
using the area space as a return air plenum. With ducted
supply air, if the minimum clearances to combustible
materials and service access are observed, the above
installations are suitable.