EasyManuals Logo
Home>Trane>Heat Pump>4TWX8

Trane 4TWX8 User Manual

Trane 4TWX8
24 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
Trane - by Trane Technologies (NYSE: TT), a global climate innovator - creates comfortable, energy efficient indoor
environments for commercial and residential applications. For more information, please visit trane.com or
tranetechnologies.com.
The AHRI Certified mark indicates Trane U.S. Inc. participation in the AHRI Certification program. For verification of individual certified products,
go to ahridirectory.org.
Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed
to using environmentally conscious print practices.
© 2020 Trane
18-BC91D1-6B-EN 22 May 2020
Supersedes 18-BC91D1-6A-EN (February 2020)
SYSTEM FAULTS
REFRIGERANT CIRCUIT
Head Pressure To o High
Head Pressure To o Low
Suction Pressure To o High
Suction Pressure To o Low
Liquid Refrig. Floodback (TXV/EEV)
Liquid Refrig. Floodback
(Cap. Tube)
I.D. Coil Frosting
Compressor Runs
Inadequate or No Cooling/Htg
ELECTRICAL
Compressor & O.D. Fan
Won’t Start
Compressor Will Not Start
But O.D. Fan Runs
O.D. Fan Won’t Start
Compressor Hums But Won’t Start
Compressor Cycles on IOL
I.D. Blower Won’t Start
DEFROST
Unit Won’t Initiate Defrost
Defrost Terminates on Time
Unit Icing Up
WHAT TO CHECK MODE
POWER SUPPLY
HIGH VOLTAGE WIRING
COMPRESSOR IOL
RUN CAPACITOR
START CAPACITOR
START RELAY
CONTACTOR CONTACTS
LOW VOLTAGE WIRING
CONTR
OL TRANSFORMER
THERMOSTAT
CONTACTOR COIL
LOW VOLTAGE FUSE
STUCK COMPRESSOR
INEFFICIENT COMP.
REF. UNDERCHARGE
REF. OVERCHARGE
EXCESSIVE EVAP. LOAD
NONCONDENSABLES
RES. O.D. AIRFLOW
O.D. AIR RECIRCULATION
TXV/EEV STUCK OPEN
SUPERHEAT
RES. I.D. AIRFLOW
REF. CIR. RESTRICTIONS
SOV LEAKING
SOV COIL DEFECTIVE
CHECK VALVE LEAKING
*
DEFROST RELAY DEF.
DEFROST CONTROL DEF.
C
H
C
H
C
H
C
H
C
H
C
H
C
H
C
H
C
H
C
H
C
H
C
H
C
H
C
H
C
H
C
H
C
H
P
P
P
P
P
P
P
P
P
P
P
P
P
P
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
P
P
P
P
S
S
S
S
P
P
P
P
S
S
P
P
P
P
P
P
P
P
P
P
P
P
P
P
S
S
S
S
S
S
S
S
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
S
S
S
S
S
S
S
P
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
P
P
S
S
S
S
S
S
S
S
S
S
S
S
P
P
P
P
P
P
S
S
S
S
S
S
S
S
S
S
S
P
P
S
S
S
S
S
S
S
S
P
P
P
P
P
P
P
S
S
PP
P
P
C - Cooling H - Heating P - Primary Causes S - Secondary Causes
*
- 3 Phase Only
15.2 Troubleshooting