16
Pub. No. 22-1840-14
NOTE:
CONTINUOUS fan
mode during COOLING
operation may not be
appropriate in humid
climates. If the indoor
air exceeds 60% relative
humidity or simply feels
uncomfortably humid,
it is recommended that
the fan only be used in
the AUTO mode.
TDHM AIRFLOW - COOLING
0.1 0.3 0.5 0.7 0.9
CFM 458 456 477 481 491
Watts 28 52 73 92 118
CFM 487 485 504 507 515
Watts 32 56 77 97 124
CFM 516 514 532 533 540
Watts 36 61 82 104 132
CFM 545 543 559 560 564
Watts 40 66 88 111 141
CFM 574 572 586 586 589
Watts 45 72 95 120 151
CFM 617 615 627 625 625
Watts 54 81 107 135 169
CFM 660 658 668 665 662
Watts 63 91 120 152 189
CFM 689 687 695 691 686
CFM 598 596 609 608 609
Watts 50 77 101 128 161
CFM 636 634 645 643 641
Watts 58 85 113 142 177
CFM 675 673 682 678 674
Watts 66 95 125 158 196
CFM 713 711 718 713 706
Watts 76 105 139 175 216
CFM 752 750 754 748 739
Watts 87 117 154 193 236
CFM 810 808 809 800 788
Watts 104 136 178 222 269
CFM 868 866 863 853 836
Watts 125 159 205 253 301
CFM 906 904 900 888 869
Watts 140 175 223 274 323
CFM 738 735 741 735 727
Watts 82 113 148 186 228
CFM 786 784 786 778 767
Watts 97 128 168 210 255
CFM 834 832 831 822 808
Watts 112 145 189 235 282
CFM 882 880 877 866 849
Watts 130 164 212 261 310
CFM 930 928 922 909 889
Watts 150 186 236 287 337
CFM 1003 1000 990 975 950
Watts 183 222 274 326 375
CFM 1075 1073 1059 1041 1011
Watts 220 263 314 364 408
CFM 1123 1121 1104 1084 1052
Watts 248 294 341 389 427
CFM 877 875 872 861 845
Watts 128 162 209 258 307
CFM 935 933 927 914 893
Watts 152 188 238 289 339
CFM 993 991 981 966 942
Watts 178 217 268 321 370
CFM 1051 1049 1036 1019 991
Watts 207 249 300 352 398
CFM 1109 1106 1090 1071 1040
Watts 239 284 333 381 422
CFM 1195 1193 1172 1150 1113
Watts 294 345 384 422 449
CFM 1282 1280 1254 1229 1186
Watts 357 414 436 456 463
CFM 1334 1351 1272 1201 1125
Watts 405 466 463 459 455
Notes:
1. * First letter may be "A" or "T".
2. ^ Letter may be "A" through "Z"
3. ** Factory setting.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID CLIMATE setting;
NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
2.5
3
290 CFM/ton
330 CFM/ton
310 CFM/ton
*DHMB060BCV3VB^ Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
Cooling
Airflow Setting
Size (tons)
1.5
2
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
290 CFM/ton
310 CFM/ton
330 CFM/ton
450 CFM/ton
290 CFM/ton
310 CFM/ton
310 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton
430 CFM/ton
450 CFM/ton
290 CFM/ton
430 CFM/ton
450 CFM/ton
330 CFM/ton
350 CFM/ton
370 CFM/ton
400 CFM/ton