9
Pub. No. 22-1840-14
TUHM AIRFLOW - HEATING
Temp. Rise 61 59 58 59 60
Temp. Rise 58 56 55 56 57
Temp. Rise 55 53 53 53 54
Temp. Rise 50 48 48 48 49
CFM 1048 1065 1060 1052 1038
Temp. Rise 60 59 59 60 61
Watts 149 169 208 252 358
CFM 1107 1123 1116 1108 1094
Temp. Rise 57 56 56 57 58
Watts 167 186 226 271 386
CFM 1165 1181 1173 1165 1150
Temp. Rise 54 53 54 54 55
Watts 187 204 245 292 417
CFM 1291 1304 1293 1284 1269
Temp. Rise 49 48 49 49 50
Watts 236 250 293 343 490
CFM 1466 1476 1461 1451 1435
Temp. Rise 60 59 60 60 61
Watts 319 330 374 430 613
CFM 1548 1556 1540 1529 1512
Temp. Rise 57 56 57 57 58
Watts 364 373 419 476 679
CFM 1629 1637 1618 1608 1590
Temp. Rise 54 54 54 54 55
Watts 413 419 467 527 750
CFM 1803 1807 1785 1774 1755
Temp. Rise 49 48 49 49 50
Watts 529 532 582 646 864
*UHMC100ACV4VB^ Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Target Airflow
(See Note 5)
Temp. Rise 62 59 57 56 55
Temp. Rise 58 56 54 53 53
Watts 113 107 111 113 133
Temp. Rise 55 53 52 51 50
Watts 108 107 122 135 160
Temp. Rise 52 50 49 49 48
Watts 104 108 135 160 191
CFM 1213 1232 1237 1232 1220
Temp. Rise 60 60 59 60 60
Watts 131 160 253 345 405
CFM 1279 1297 1299 1290 1274
Temp. Rise 57 57 56 57 58
Watts 147 178 281 382 445
CFM 1353 1369 1367 1355 1335
Temp. Rise 54 54 54 54 55
Watts 168 201 313 423 489
CFM 1434 1448 1443 1426 1402
Temp. Rise 51 51 51 51 52
Watts 197 229 352 469 538
CFM 1699 1707 1690 1659 1621
Temp. Rise 60 60 60 61 63
Watts 325 349 495 628 698
CFM 1790 1797 1775 1740 1696
Temp. Rise 57 57 57 59 60
Watts 382 400 551 685 752
CFM 1892 1896 1870 1830 1781
Temp. Rise 54 54 54 56 57
Watts 453 462 616 750 813
CFM 2004 2006 1975 1929 1873
Temp. Rise 51 51 52 53 54
Watts 540 538 694 822 880
*UHMD120ACV5VB^ Furnace Heating Airflow (CFM) and Power (Watts) vs. External Static Pressure With Filter
Target Airflow
(See Note 5)
Notes:
1. * First letter may be "A" or "T".
3. ** Factory setting.
2. ^ Letter may be “A” through “Z”.
4. Continuous Fan Setting: Heating or cooling airflow is approximately 50% of selected
cooling value.
5. LOW 350 cfm/ton is recommended for variable speed application for COMFORT & HUMID
CLIMATE setting; NORMAL is 400 cfm/ton; HIGH 450 cfm/ton is for DRY CLIMATE setting.
6. Target airflow is field selectable for high (100%) heat. Target airflow for low and medium
heat are percentages of high heat and are not field selectable.