VAV-SVX08R-EN
7
Digit 12, 13, 14, 15 — Controls
(continued)
DD87 = UC210 DDC- Basic plus- Local
(Water heat- N.C. 2-position) Remote
(Water- Modulating)
DD88 = UC210 DDC- Basic plus- Local
(Water heat- N.O. 2-position) Remote
(Water- N.O. 2-position)
DD89 = UC210 DDC- Basic plus- Local
(Water heat- N.C. 2-position) Remote
(Water- N.C. 2-position)
DD90 = UC210 DDC- Basic plus- Local
(Water heat- N.O. 2-position) Remote
(Water- N.C. 2-position)
DD91 = UC210 DDC- Basic plus- Local
(Water heat- N.C. 2-position) Remote
(Water- N.O. 2-position)
DD92 = UC210 DDC- Basic plus- Local
(Electric heat- Staged) Remote (Staged EH)
DD93 = UC210 Ventilation Flow (Water heat-
N.O. 2-position)
DD95 = UC210 Basic (Electric Heat
Modulating SCR)
DD96 = UC210 Basic plus- Local (Electric
heat-Modulating SCR) Remote (Staged EH)
DD97 = UC210 Ventilation Flow (Electric
heat-Modulating SCR)
ENCL = Shaft Only in Enclosure
FM00 = Other Actuator and Control
FM01 = Trane Supplied Actuator, Other Ctrl
N.C. = Normally-Closed
N.O. = Normally-Open
FM = Factory Installation of Customer-
supplied Controllers
Digit 16 — Insulation
A = 1/2” Matte-faced
B = 1” Matte-faced
D = 1” Foil-faced
F = 1” Double Wall
G = 3/8” Closed-cell
Digit 17, 18— Not Used
00 = Not Applicable
Digit 19— Outlet Plenum (Slip-and-
Drive Connection
0 = None
A = 1 Outlet RH
B = 1 Outlet END
C = 1 Outlets, LH
D = 2 Outlets, 1RH, 1END
E = 2 Outlets, 1LH, 1END
F = 2 Outlets, 1RH, 1LH
H = 3 Outlets, 1LH, 1RH, 1END
J = 4 Outlets, 1LH, 1RH, 2END
Note: See unit drawings for outlet sizes/
damper information.
Digit 20— Not Used
0 = Not Applicable
Digit 21— Water Coil
0 = None
1 = 1 Row
2 = 2 Row
3 = 3 Row
4 = 4 Row
A = 1 Row Premium
B = 2 Row Premium
C = 3 Row Premium
D = 4 Row Premium
Digit 22— Electrical Connections
F = Able to Flip for LH/RH Connections (VCEF
Only)
L = Left, Airflow hits in face
R = Right, Airflow hits in face
0 = Opposite side connection, coil and control
(VCWF Only)
Note: VCCF/VCWF can be flipped in field for
opposite connections.
Digit 23— Transformer
0 = None
1 = 120/24V, 50 VA
2 = 208/24V, 50 VA
3 = 240/24V, 50 VA
4 = 277/24V, 50 VA
5 = 480/24V, 50 VA
6 = 347/24V, 50 VA
7 = 380/24V, 50 VA
8 = 575/24V, 50 VA
Note: For VCEF units with transformers the
VA depends on the staging, control,
and contactor type (ranges are 50 VA
or 75 VA)
Digit 24 — Disconnect Switch
0 = None
W = With
Note: VCCF/VCWF— toggle disconnect.
VCEF-door interlocking power
disconnect.
Digit 25 — Power Fuse
0 = None
W = With
Digit 26 — Electric Heat Voltage
0 = None
A = 208/60/1
B = 208/60/3
C = 240/60/1
D = 277/60/1
E = 480/60/1
F = 480/60/3
G = 347/60/1
H = 575/60/3
J = 380/50/3
K = 120/60/1
Digit 27, 28, 29 — Electric Heat kW
000 = None
010 = 1.0 kW
015 = 1.5 kW
460 = 46.0 kW
Notes:
• 0.5 to 8.0 kW in 1/2 kW
increments
• 8.0 to 18.0 kW in 1 kW
increments
• 18.0 to 46.0 kW in 2 kW
increments
Digit 30 — Electric Heat Stages
0 = None
1 = 1 Stage
2 = 2 Stages Equal
3 = 3 Stages Equal
Digit 31 — Electric Heat Contactors
0 = None
1 = 24V Magnetic
5 = 0–10Vdc SCR Heat; UC400/UC210
6 = 0–10Vdc SCR Heat; FMTD/ENCL/DD00
7 = 24V SSR (Solid State Relay)
Digit 32, 33— Not Used
00 = Not Applicable
Digit 34 — Actuator
0 = Standard
A = Spring Return, Normally Open
B = Spring Return, Normally Closed
C = Belimo™ Actuator
G = Trane Analog Actuator (UC210 or UC400
only)
Digit 35 — Sensor Options
0 = Standard, Wired
3 = Trane Air-Fi® Wireless Communications
Interface
Digit 36 — Pre-wired Factory
Solutions
0 = None
1 = Factory-mounted DTS
2 = HW Valve Harness
3 = Both DTS/HW Valve Harness
4 = Averaging DTS Factory-installed in Unit
(Required UC210/UC400 w/SCR Heat)
5 = Analog HW Valve, field provided
6 = Factory-mounted DTS and HWV Harness
MMooddeell NNuummbbeerrss