Functions.
1 = setting scale. 2 = time settings. 3 = temperature settings. 4 = on. 5 = off.
Temperature setting.
(The heater must be switched on)
Press TEMP – the previous temperature setting is displayed.
The numbers indicate a rising temperature scale. Experiment to find the temperature
that suits you best. Begin for example by turning the thermostat dial to position 4. If you
later find that you would prefer a higher or lower temperature, adjust the dial up or down
until you find the ideal bathing temperature for you (usually 70-90°C (158-194°F) for
traditional dry and wet sauna baths, 40-45°C (104-113°F) for steam saunas and herb
saunas).
Manual on/off.
Press ON to switch the facility on. Press OFF to switch it off. (the LED goes out).
A memory function automatically sets the previous temperature.
Press TEMP – to change the pre-set temperature.
The built-in timer automatically switches the sauna heater/steam generator off after
3 hours. If you want to switch it off earlier than that, press OFF. To extend the sauna
time, press ON.
Timer settings.
(The heater must be switched off)
The numbers in this case represent the timer times (= the number of hours until the
heater automatically switches on). To set the timer:
Press TIME – use the arrow keys to select the desired pre-set time, 1–10 hours.
Press ON – the timer is activated and the time indicator blinks during the pre-set time
period. Once the heater switches itself on, it remains on for 3 hours, after which it
automatically switches itself off. If you want to switch it off earlier than that, just press
OFF. To extend your sauna time, press ON.
Main power switch.
To be changed more than once: At the bottom of the relay box, the SE unit and the
smaller types of steam generators is a main power switch that disconnects the heater
entirely from the electrical supply. This main switch should only be used if the sauna will
not be used for a longer period, such as several weeks. To be changed more than once:
The memory function must be reset each time the power is interrupted.
INSTRUCTIONS FOR USE
CC 50
Functions.
1 = lighting. 2 = on/off. 3 = temperature setting. 4 = time setting. 5 = reduce temperature/time.
6 = increase temperature/time. 7 = display.
Lighting.
Lights automatically when the facility starts and switches off automatically when the
facility shuts down. You can also switch the lighting on or off manually by pressing
LIGHT.
Main power switch.
To be changed more than once: At the bottom of the relay box, the SE unit and the
smaller types of steam generators is a main power switch that disconnects the heater
entirely from the electrical supply. This main switch should only be used if the sauna will
not be used for a longer period, such as several weeks. To be changed more than once:
The memory function must be reset each time the power is interrupted.
The thermometer in the sauna/steam bath should be placed at such a height that the
temperature corresponds exactly to the numbers in the panel of the CC 50.
SETTINGS
CC 50, all models
Setting the bathing temperature.
Press TEMP – the previous temperature is displayed. Use the up and down arrows (
) to change the temperature.
Manual on/off.
Press ON to switch the facility on. Press OFF to switch it off. (the LED goes out). If
you forget to switch off the generator manually, it switches off automatically after 3 or 12
hours - depending on the type of control panel.
Timer settings.
(The sauna must be switched off)
Press TIME (the hour digits blink) – set the number of hours until you want to use the
sauna using the up and down arrows (
).
Press TIME (the minute digits blink) – set the number of minutes until you want to use
the sauna using the up and down arrows (
).
(Important: The hour or minute digits must be blinking before you press ON).
Press ON – the on time is activated and a red LED blinks until the sauna automatically
starts after the pre-set time. The heater switches off automatically after 3 or 12 hours –
depending on the type of control panel.
You can switch off the sauna manually at any time by pressing OFF.
Changing the type of panel (Factory settings = Test no. 50),
1. Connect the voltage.
2. Press
and
at the same time for approx. 6 sek (max. 60 sek. after the
voltage is connected).
3. Change the type of panel according to the scheme with
and
, approve
with TEMP.
Panel type
Test no.
*
Test no.
**
Description
CC50-3B 50 50.A Sauna 110°C, 3 h running time
CC50-12B 51 51.A Sauna 110°C, 12 h running time
CC50-3S 53 53.A Steam 55°C, 3 h running time
CC50-12S 54 54.A Steam 55°C, 12 h running time
CC50-1S 15 15.A Steam 55°C, 1 h running time
CC50-1B 18 18.A Sauna 110°C, 1 h running time
CC50-24B 58 58.A Sauna 110°C, 24 h running time
CC50-0B 59 59.A Sauna 110°C, ON/OFF
CC50-24S 68 68.A Steam 55°C, 24 h running time
CC50-0S 69 69.A Steam 55°C, ON/OFF
* Settings at ev. use of extern switch with impulse function.
** Settings at ev. use of extern switch with ON/OFF function.
Code lock to prevent settings from being changed.
First program as ”Settings”, press on the down arrow (
), hold it down and press TEMP
and TIME at the same time. The code lock, which prevents changing of settings, is now
activated. To return to unlocked mode, press the down arrow (
), hold it down and
press OFF at the same time.
Code lock that prevents changing of the temperature setting.
First program as ”Settings”, press TIME, hold it down and press TEMP and LIGHT at
the same time. The code lock, which prevents changing of the temperature settings, is
now activated. To return to unlocked mode, press the down arrow (
), hold it down and
press OFF at the same time.